Skip to content

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Aug 2026 · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · Vol 1282, pp. 125249 · 0 citations · 16 references
Medicine

TL;DR

A novel LC-MS/MS method that was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Abstract

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000 ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

View source

Similar papers

Open access Sep 2026

Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

A sensitive, reliable, and rapid UPLC–MS/MS method was developed and validated for the simultaneous determination of ensartinib and M465 in rat plasma and applied to a rat pharmacokinetic study and provides useful analytical support for further preclinical investigations of ensartinib and its major metabolite.

Shi-Qi Jiang, Yan Chen, Lu Cao et al. · 0 citations
Open access Sep 2026

SIL-IS LC-MS/MS method for rapid quantification of phloroglucinol in human plasma: development, validation and application to a pharmacokinetic study.

A sensitive, rapid, and robust liquid chromatography-tandem mass spectrometry method incorporating a stable isotope-labeled internal standard incorporating phloroglucinol-13C6 was developed and validated and successfully applied to a pharmacokinetic and bioequivalence study of phloroglucinol orally disintegrating table...

Qi-Qin Sun, Xiang-Hong Li, Yun-Jie Dong et al. · 0 citations
Open access Sep 2026

Development and validation of an LC-MS/MS method for the novel PROTAC KT-474 in rat and mouse plasma: Application to dose-dependent pharmacokinetics and metabolite identification in mice.

A sensitive liquid chromatography-tandem mass spectrometry method is developed and validated for the quantification of KT-474 in rat and mouse plasma and successfully applied it to pharmacokinetic studies in mice, providing a comprehensive characterization of the pharmacokinetic and metabolic properties of KT-474.

Ji-Hoon Oh, Dang-Khoa Vo, H. Maeng · 0 citations
Open access Sep 2026

LC-MS/MS Method for Simultaneous Quantification of Zolpidem, Zopiclone, and Their Metabolites in Human Urine and Its Pharmacokinetic Application.

The method's potential for retrospective urinary screening of Z-drug exposure in forensic and clinical toxicology is supported, and its potential for retrospective urinary screening of Z-drug exposure in forensic and clinical toxicology is supported.

Varsha Chauhan, Manu Sharma, Murtada Taha et al. · 0 citations
Open access Sep 2026

A sensitive and high-throughput LC-MS/MS method for the determination of ibuprofen: Application to a gender-comparative pharmacokinetic study

A sensitive and reliable ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ibuprofen in plasma to investigate the pharmacokinetics of ibuprofen after oral administration of ibuprofen sustained-release capsules.

Mei-Ah Yang, Kui He, Yu-Jie Mo et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.