Skip to content
Review Open access

CT-based deep learning auto-segmentation of high-risk clinical target volume in CT-guided cervical cancer brachytherapy: a single-center pragmatic study

Sep 2026 · Frontiers in Oncology · Vol 16 · 0 citations · 48 references
Medicine

TL;DR

3D U-Net provided the most favorable overall performance among the evaluated architectures for intact-cervix cases and support further physician-supervised implementation, followed by multicenter external validation and cohort-level dosimetric assessment.

Abstract

Introduction Computed tomography (CT)-based high-risk clinical target volume (HR-CTV) auto-segmentation has been previously investigated, but evidence remains heterogeneous across applicators, target definitions, architectures, and clinical evaluation procedures. A pragmatic within-cohort benchmark of 2D U-Net, 3D U-Net, and nnFormer was performed in a CT-only, applicator-in-situ workflow. Methods CT images from 544 brachytherapy fractions in 182 patients were analyzed, including 509 fractions from 163 patients treated with tandem-and-ovoid applicators and 35 fractions from 19 patients treated with vaginal cylinders. All fractions from a patient remained in one partition (HR-CTVc: 325/82/102 fractions; HR-CTVv: 22/6/7 fractions). Only seven test fractions were available and thus the postoperative HR-CTVv analysis was exploratory. Performance was assessed using Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95), average surface distance (ASD), and physician consensus edit categories. Task-level CT normalization parameters were estimated exclusively from the training partition and fixed for validation and testing; spatial cropping was image centered and contour independent. Results In the intact-cervix test cohort, 3D U-Net showed the most favorable descriptive combination of overlap and surface agreement (DSC 0.848 ± 0.059; HD95 2.755 ± 1.688 mm; ASD 1.008 ± 0.622 mm). In the exploratory vaginal stump cohort, corresponding values were 0.788 ± 0.060, 4.724 ± 2.434 mm, and 2.917 ± 2.150 mm. On physician consensus review, 91/102 HR-CTVc and 6/7 HR-CTVv 3D U-Net contours required no or localized correction. In an ancillary 20-fraction independent-contouring analysis, physician-to-physician HR-CTV agreement was DSC 0.80 ± 0.06 and HD95 3.4 ± 1.8 mm. Conclusions In this internally validated CT-guided cohort, 3D U-Net provided the most favorable overall performance among the evaluated architectures for intact-cervix cases. The postoperative results provide a preliminary feasibility signal, and confirmation in a larger cohort is required. These findings support further physician-supervised implementation, followed by multicenter external validation and cohort-level dosimetric assessment.

Read PDF

Similar papers

Open access Oct 2026

Deep learning-based segmentation of non-perfused volume after magnetic resonance guided high-intensity focused ultrasound therapies: a retrospective evaluation on clinical patient data.

A deep learning-based automatic NPV segmentation model that demonstrates reliable volumetric assessment with minimal slice-level omission, supporting integration into routine MR-HIFU treatment workflows is developed and clinically evaluated.

Chen-Chen Bing, T. Sainio, Ari Partanen et al. · 0 citations
Open access Oct 2026

External evaluation of a deep learning-based algorithm for automated lung tumor and esophagus segmentation on CBCT

Online adaptive radiotherapy requires fast and accurate delineation of targets and organs at risk on cone-beam computed tomography (CBCT). Although deep learning (DL)-based CBCT auto-segmentation methods have been proposed, their clinical generalizability remains insufficiently validated. This study aimed to externally...

Zhe-Hao Zhang, D. Hobbis, Jue Jiang et al. · 0 citations
Open access Sep 2026

Efficient deep learning-driven workflows for accelerated single-fraction radiation therapy planning of a solitary tumour in the lung

Two deep learning dose prediction-driven workflows could generate a clinically acceptable plan in less than ten minutes for same-day, single-fraction treatment of a tumour in the lung.

M. Gaudreault, N. Hardcastle, K. Woodford et al. · 0 citations
Oct 2026

Impact of multisequence MRI on deep learning-based dose prediction for glioblastoma radiotherapy: A comparative evaluation of CT-only and CT+MRI models.

INTRODUCTION Deep learning-based dose prediction has emerged as a promising approach for supporting automated radiotherapy planning workflows by estimating three-dimensional dose distributions from patient imaging. Although planning CT remains the standard imaging modality, multisequence MRI provides anatomical and tis...

S. Singh, S. Sen, A. Singh et al. · 0 citations
Preprint Sep 2026

Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices

Background and purpose: Dose Volume Histogram (DVH) indices remain the main dose-effect metrics for toxicity prediction, but they depend on how contours were made. Inter-observer variability (IOV) is unavoidable and clinically accepted, so the question for automatic segmentation addresses equivalence: do automatic cont...

Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.