Skip to content

Impact of multisequence MRI on deep learning-based dose prediction for glioblastoma radiotherapy: A comparative evaluation of CT-only and CT+MRI models.

Oct 2026 · Radiography · Vol 32 7, pp. 103585 · 0 citations · 34 references
Medicine

Abstract

INTRODUCTION Deep learning-based dose prediction has emerged as a promising approach for supporting automated radiotherapy planning workflows by estimating three-dimensional dose distributions from patient imaging. Although planning CT remains the standard imaging modality, multisequence MRI provides anatomical and tissue-characterization information that may improve prediction accuracy in glioblastoma (GBM) radiotherapy. This study investigated the incremental value of multisequence MRI by comparing CT-only and CT + MRI models using an identical framework.

Methods

A retrospective cohort of 140 patients with GBM treated with conventionally fractionated radiotherapy (60 Gy in 30 fractions) was analyzed. Two 3D Attention U-Net models were developed: CT-only and CT + MRI incorporating T1-weighted gadolinium-enhanced (T1GD), FLAIR, and T2∗ MRI sequences. Patients were divided into training (n = 100), validation (n = 20), and test (n = 20) cohorts. Models were trained for 130 epochs using Adam optimizer with a composite loss function of 70% mean absolute error (MAE) and 30% mean squared error.

Results

The CT + MRI model achieved lower MAE than CT-only (5.99 ± 1.45 Gy vs. 6.92 ± 1.74 Gy, p = 0.006). D2 error decreased from 3.51 ± 1.61 Gy to 1.53 ± 1.53 Gy. SSIM improved from 0.564 ± 0.102 to 0.599 ± 0.134 (p = 0.017), and PSNR increased from 16.84 ± 2.17 dB to 18.01 ± 1.92 dB (p = 0.009). Pearson correlation coefficients were 0.929 and 0.937 for CT-only and CT + MRI models, respectively.

Conclusion

Multisequence MRI improved deep learning-based dose prediction for GBM radiotherapy, particularly spatial dose agreement and high-dose region estimation. Further multicentre validation is required. IMPLICATIONS FOR PRACTICE MRI-enhanced dose prediction may support automated planning workflows by improving predicted dose distributions.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.