Skip to content
Open access

Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950

Sep 2026 · European Radiology · 1 citation · 31 references
Medicine

TL;DR

The proposed model provided a promising, clinically relevant alternative to LAA-950, improving accuracy and consistency in emphysema quantification and further aligning with radiologist assessments and lung function metrics.

Abstract

Objectives To develop a deep learning segmentation algorithm to enable accurate, reliable emphysema quantification while improving agreement with radiologist assessments and pulmonary function tests. Materials and methods The model was developed using retrospective virtual and clinical datasets. Virtual data enabled pre-training using ground truth across controlled parameters, including scanners, doses, and reconstruction kernels, while clinical data enabled fine-tuning with expert-annotated emphysema masks. Segmentation accuracy was quantified using the Dice coefficient, and robustness was quantified using emphysema percentage consistency across imaging conditions. Model-based emphysema percentage was correlated with Fleischner visual scores (ordinal; 0–5) and pulmonary function tests (DLCO, FEV1pp, and FEV1/FVC) and compared to LAA-950. Statistical analysis included univariate/multivariate correlations. Quantitative assessment included Dice, bias, limits of agreement, and reproducibility coefficient. Results Virtual data included 20 human models (mean age: 43 years ± 11 [SD], 10 men), and clinical data included multi-center cohorts of 101 patients (C1; 57 years ± 8, 54 men), 23 patients (C2; 57 years ± 7, 14 men), and 1159 patients (C3; 65 years ± 9, 586 men). The model outperformed LAA-950 in segmentation accuracy, achieving higher Dice scores across virtual (76.6% ± 8.8 vs 51.5% ± 23.5), C1 (48.4% ± 24.2 vs 22.5% ± 20.2), and C2 (64.8% ± 9.3 vs 32.7% ± 16.8) cohorts. Furthermore, analysis showed improved bias and limits of agreement (C1; 1.0% ± 4.3 vs 2.1% ± 15.1) and stronger correlations with visual scoring (C1; 0.77 vs 0.47) and pulmonary function tests (C3; DLCO multivariate R2: 0.31–0.32 vs 0.21–0.25). Conclusion The proposed model provided a promising, clinically relevant alternative to LAA-950, improving accuracy and consistency in emphysema quantification and further aligning with radiologist assessments and lung function metrics.

Read PDF

Similar papers

Open access Sep 2026

Automated CT-Based Quantification of Pulmonary Fibrosis Using Deep Learning-Based Lung Segmentation

Background/Objectives: To develop and evaluate an automated CT-based framework for the quantitative assessment of fibrotic interstitial lung disease (ILD), including idiopathic pulmonary fibrosis (IPF), using a standardised six-level anatomical protocol and deep-learning lung segmentation. Methods: The segmentation dat...

Wen-Chien Cheng, Wei-Chih Liao, Chia-Hung Chen et al. · 0 citations
#software testing Review Open access Aug 2026

Clinical evaluation of novel deep learning‐based auto‐segmentation software: Utility and potential pitfalls

RatoGuide demonstrated favorable performance in typical cases, but accuracy declined in atypical cases with artifacts or altered anatomy, particularly for atypical cases and organs in high-dose gradient regions.

R. Tozuka, M. Saito, Masaki Matsuda et al. · 0 citations
Open access Oct 2026

Deep learning-based segmentation of non-perfused volume after magnetic resonance guided high-intensity focused ultrasound therapies: a retrospective evaluation on clinical patient data.

A deep learning-based automatic NPV segmentation model that demonstrates reliable volumetric assessment with minimal slice-level omission, supporting integration into routine MR-HIFU treatment workflows is developed and clinically evaluated.

Chen-Chen Bing, T. Sainio, Ari Partanen et al. · 0 citations
Aug 2026

Automated Standardization of the Shear-wave Elastography Effective Region Using DeepLabV3 Improves Malignancy Assessment in Thyroid Nodules: A Single-institution Multicampus Study.

RATIONALE AND OBJECTIVES To assess whether a DeepLabV3-based model can standardize the shear-wave elastography (SWE) effective region in thyroid nodules and improve maximum Young's modulus (Emax)-based malignancy assessment. MATERIALS AND METHODS This retrospective single-institution multicampus study included 678 tr...

Lei Hu, Min Tang, Xiahui Ren et al. · 0 citations