Skip to content
Open access

Automated CT-Based Quantification of Pulmonary Fibrosis Using Deep Learning-Based Lung Segmentation

Sep 2026 · Diagnostics · Vol 16 · 0 citations · 21 references
Medicine

Abstract

Background/Objectives: To develop and evaluate an automated CT-based framework for the quantitative assessment of fibrotic interstitial lung disease (ILD), including idiopathic pulmonary fibrosis (IPF), using a standardised six-level anatomical protocol and deep-learning lung segmentation. Methods: The segmentation dataset comprised 3315 manually annotated development slices from 92 patients and a non-overlapping internal holdout of 845 slices from 5 patients. A separate 100-study localisation/scoring set yielded a 97-patient agreement cohort (84 IPF, 13 other ILD; 1164 per-level, per-lung observations) after three DICOM-conversion exclusions. YOLO11n-seg masks underwent vessel- and structure-removal fibrosis detection. The radial spatial score was compared with a non-blind expert-adjudicated reference; the per-level Fibrosis Index was an auxiliary read-out. Results: On the five-patient internal segmentation holdout, mean intersection over union (mIoU) was 0.926 ± 0.017; the in-sample development value was approximately 0.95. Model-only latency was 73.8 ± 9.7 ms/slice at batch size 1, and peak throughput was 1.48 ms/slice at batch size 512. In the separate 97-patient agreement cohort, the expert-adjudicated score was identical to the automated score for 967 of 1164 observations (83.1%) and differed for 197 (16.9%). In the modified-score subset, Pearson r was 0.918, mean absolute error was 3.07, and ICC(2,1) was 0.889 (patient-clustered 95% CI 0.828–0.923). The pooled ICC(2,1) was 0.988 (0.982–0.992), but this value was inflated because the 967 unchanged pairs were identical by construction. Sequential end-to-end processing, measured in seven study patients, took a mean of 22.5 s per patient (median 24.0 s, range 17.3–24.9 s); localisation accounted for 88.1% of this time. Conclusions: The framework combined lung segmentation, anatomically standardised sampling, and automated fibrosis scoring. The radial score showed preliminary analytical concordance under non-blind expert adjudication. The fibrosis detector remains a proof-of-concept implementation based on 8-bit windowed images and has not been compared with independently drawn pixel-level fibrosis masks. The radial partition is an exploratory scoring convention and was not compared with alternative partitions or validated against clinical outcomes. Larger external studies using native Hounsfield-unit data and independent blinded readers are required.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.