Skip to content
Open access

Uncertainty estimation for reliable neural network-based radiotherapy dose modelling using Monte Carlo dropout, mean variance estimation and deep ensemble

Aug 2026 · Physics and Imaging in Radiation Oncology · Vol 41, pp. 101072 · 0 citations · 42 references
Medicine

TL;DR

All methods provided meaningful uncertainty estimates clearly associated with prediction error, and MVE showed the lowest ENCE and strongest correlation with MAE while requiring the least computation.

Abstract

Background and Purpose Neural networks promise fast dose modelling with high accuracy for challenging situations like magnetic resonance imaging (MRI)-guided radiotherapy. As they are data-driven, failure can occur and early identification of erroneous dose calculations is required. In this study, we implemented and evaluated three uncertainty estimation techniques to assess whether they can indicate increased prediction error. Materials and methods Using a dataset of 6713 radiotherapy segments from 130 1.5 T MRI linear accelerator plans and a 3D UNet for dose modelling, three techniques were implemented to assess uncertainty: Monte Carlo dropout (MCD), mean variance estimation (MVE) and a deep ensemble (DE). All methods were evaluated regarding calibration using the expected normalized calibration error (ENCE) and correlation to mean absolute error (MAE). Cumulative failure rates were calculated across uncertainty thresholds, with a 3 mm/3% gamma passing rate < 95% defining failure. Results After calibration, all three methods showed ENCE values of 0.14/0.05/0.10 for MCD/MVE/DE. A strong relationship between mean uncertainty and MAE was observed, reflected by high Spearman correlation coefficients (MCD: ρ = 0.64, MVE: ρ = 0.76, DE: ρ = 0.67). Failure rates increased with mean uncertainty across all methods, enabling thresholds targeting a 10% failure rate. On independent evaluation, 44%–77% of segments were accepted, with observed failure rates among accepted segments of 7.2%–9.5%. Conclusions All methods provided meaningful uncertainty estimates clearly associated with prediction error. MVE showed the lowest ENCE and strongest correlation with MAE while requiring the least computation. DE most closely matched the target failure rate while flagging the fewest segments.

Read PDF

Similar papers

Aug 2026

Physics in Medicine & Biology

UNetrDose demonstrated high fundamental accuracy at the individual beamlet level, where pass rates for the stringent γ criterion exceeded 96% for both esophageal and rectal cases, and translated to excellent clinical performance on full IMRT plans.

Qiang Wang, Ying Song, Sen Bai et al. · 0 citations
Preprint Sep 2026

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

This work replaces the standard MSE training objective with a differentiable $\gamma$-index-based loss, extended to native 3D operation, and demonstrates that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate that is critical for clinical deployment.

J. Jawaid, M. Spezialetti, Gabriele Libardi et al. · 0 citations
Preprint Sep 2026

PyDoseRT Photon: Physics-Guided Pencil-Beam Dose Calculation with Neural Priors and Residual Correction for CT and MRI

We present a hybrid, physics-based analytical pencil-beam (PB) dose engine, augmented by two small frozen neural physics priors, followed by a 3-D convolutional residual-correction network (U-Net). We address the DoseRAD2026 (https://doserad2026.grand-challenge.org/) photon dose-prediction task with PyDoseRT Photon, a...

A. Simkó, L. Zimmermann, H. Fuchs et al. · 0 citations
Sep 2026

A Simple and Interpretable DVH Prediction Model: Integrating Distance-to-Target Histograms with Longitudinal Spatial Features.

OBJECTIVES To develop a simple, interpretable dose-volume histogram prediction model for intensity-modulated radiation therapy by integrating distance-to-target histograms with longitudinal spatial features, and to evaluate its accuracy and generalizability. METHODS Using prostate cancer cases, dose-volume histograms...

Naohiro Kodani, Yuki Yoshino, Takeshi Nishimura et al. · 0 citations
Open access Aug 2026

A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning

Abstract Background Boron Neutron Capture Therapy (BNCT) utilizes high linear energy transfer (LET) charged particles from the 10B(n,α)7Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planni...

Yoonho Na, Chang-Min Lee, Kyuri Kim et al. · 0 citations