Multidimensional T 1 - T 2 Relaxation Imaging In Vivo on a Portable 0.064 T MRI Scanner

Sep 2026 · bioRxiv · 0 citations · 53 references
Biology Medicine

TL;DR

Whole-brain multidimensional T1-T2 relaxation imaging is clinically feasible on a portable 0.064 T MRI scanner and may support further developments of quantitative multidimensional imaging at ultra-low field.

Abstract

Purpose To demonstrate the feasibility of whole-brain multidimensional T1-T2 relaxation imaging on a portable 0.064 T MRI scanner. Methods A two-dimensional inversion-recovery, fast spin-echo acquisition was used to jointly encode T1 and T2 relaxation. Joint relaxation distributions were reconstructed voxel-wise using marginal-distribution constrained optimization (MADCO). The approach was evaluated in a quantitative relaxation MRI phantom and subsequently applied in vivo in a healthy volunteer. Joint distributions, marginal distributions, distribution-derived measures, and statistical dependencies between the two relaxation dimensions were examined. Results Phantom joint relaxation estimates showed good overall agreement with mono-exponential relaxation measurements and previously reported values at 0.064 T. The in vivo acquisition provided whole-brain coverage over a broad range of relaxation weightings and tissue contrasts. Reconstructed joint T1-T2 distributions showed spatially organized features across the relaxation space, including broad and overlapping relaxation components that were not fully represented by single-value relaxation maps or by either 1D marginal distribution alone. Selected regions of the joint relaxation space produced component maps with distinct spatial patterns. Statistical analysis further showed a dependence between the two relaxation dimensions, supporting the presence of added information in the joint distribution that is lost when treating T1 and T2 separately. Conclusion Whole-brain multidimensional T1-T2 relaxation imaging is clinically feasible on a portable 0.064 T MRI scanner. Joint relaxation distributions provide information beyond single-value relaxation mapping and may support further developments of quantitative multidimensional imaging at ultra-low field.

Read PDF

Similar papers

Open access Aug 2026

OPTIMIZING ECHO TIME AND REPETITION TIME FOR TISSUE CONTRAST USING DIGITAL PHANTOMS

Digital phantom simulations are leveraged to systematically evaluate the effect of varying TE and TR on tissue contrast across common anatomical structures, and validate known MRI contrast behaviors and provide scanner-agnostic TE/TR recommendations to accommodate practical clinical constraints.

Manvee Rai, Nisha Jhinkwan, Nidhi Goswami et al. · 0 citations
Sep 2026

An FA-based hybrid DTI-mixture model for multi-fiber reconstruction in diffusion MRI.

A hybrid diffusion MRI reconstruction framework combining Diffusion Tensor Imaging (DTI) and the multi-compartment non-central Wishart (MNCW) mixture model is proposed, which reduces incorrect single-fiber detections and produced fewer disoriented voxels in complex fiber configurations compared with the conventional mi...

Ashish Puri, Sanjeev Kumar · 0 citations
Preprint Oct 2026

Quiet, rapid 3D multiparametric mapping using magnetization-prepared zero echo time MRI

Purpose: To introduce and evaluate MuPa-ZTE, a quiet, rapid 3D framework combining native and magnetization-prepared zero echo time (ZTE) acquisitions for multiparametric mapping. Methods: MuPa-ZTE combines steady-state native ZTE with transient-state magnetization-prepared ZTE. Two implementations were evaluated: T2T1...

Alireza Samadifardheris, Shi-Shuai Wang, A. Solana et al. · 0 citations
Open access Aug 2026

Reproducibility of T2 relaxation time mapping in a phantom and human knee articular cartilage.

OBJECTIVE To quantify the reproducibility of knee articular cartilage T2 across a wide range of MR systems. MATERIALS AND METHODS The reproducibility of T2 relaxation time mapping was assessed by measuring the knee of a volunteer (n1.5 T = 22, n3T = 13) and a System Standard 130 phantom (n1.5 T = 19, n3T = 12) in 38...

H. Leskinen, Nea Pulkkinen, Antti Aarnio et al. · 0 citations
Open access Sep 2026

T2 relaxometry for myelin water fraction: an ex vivo brain imaging study

Introduction Myelin water imaging provides a non-invasive approach for indirectly investigating myelin content of the brain by magnetic resonance Imaging (MRI). Myelin water fraction (MWF) reflects the fraction of water signal associated with water trapped between myelin layers. Postmortem imaging provides a unique opp...

L. Sanches, Narges Taghizadehsalehabad, R. Moqadam et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.