Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT

Aug 2026 · Diagnostics · Vol 16 · 0 citations · 36 references
Medicine

TL;DR

The findings support implementing standardized protocols with automatic dual-range reconstructions to enable efficient, individualized carotid plaque assessment in clinical practice and support implementing standardized protocols with automatic dual-range reconstructions for keV selection based on plaque composition.

Abstract

Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40–50 keV and 70–80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.

Read PDF

Similar papers

Open access Sep 2026

Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retr...

Andreea I. Nica, C. Booz, G. Bucolo et al. · 0 citations
Sep 2026

Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.

For spinal implants, PCD-CT offers effective approaches for metal artifact and 120 keV is preferred and the combination of iMAR and 120 keV introduce new artifacts and requires careful consideration.

Xin-Ying Huang, Zai-Zhu Zhang, Yong An et al. · 0 citations

Current Medical Imaging

Xing-Lu Li, Xing-Yu Chen, Wen Chen et al. · 1 citation
Sep 2026

Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.

Background Use of virtual noncontrast (VNC) images from photon-counting CT (PCCT) may reduce radiation dose and support quantitative lung analysis by obviating the need for separate true noncontrast (TNC) acquisitions. Their accuracy for lung densitometry, however, has not been systematically assessed. Purpose To evalu...

Max L. Bodlien, S. Scharm, A. Hunkemöller et al. · 1 citation
Open access Aug 2026

Study on the combined application of selected virtual monoenergetic imaging, virtual non-contrast imaging, and adaptive statistical iterative reconstruction-V in head and neck CT angiography using 256-slice wide-body CT

Objective To evaluate the value of combining spectral CT-derived virtual monoenergetic imaging, adaptive statistical iterative reconstruction-V (ASIR-V), and virtual non-contrast imaging in head and neck CT angiography (CTA) for patients with cerebrovascular disease (CVD). Methods 150 patients undergoing head and neck...

Wen-Chao Li, Pei-Heng Li, Qiang Li et al. · 0 citations