With the growth of emerging data centers and electric vehicles, DC power distribution and hybrid microgrids are attracting growing attention. Due to the lack of a natural zero-crossing point in DC current, reliable DC fault protection is critical. This paper introduces a transient-minimized fault protection scheme utilizing Z-source circuit breakers (ZCBs), leveraging their unique features during the activation process. These features are analyzed to provide the theoretical foundation for achieving transient-minimized DC fault protection, which eliminates high spikes in fault current, relieves stress on power devices in the system, and enhances transient stability. The effectiveness of this method is validated through simulation tests of a 100 MVA islanded hybrid microgrid using ZCBs based on experimentally verified models. Test results demonstrate that system oscillation is reduced by 13% in frequency and 74% in voltage, while completely eliminating voltage sags. With the help of ZCBs, the system also recovers more quickly after fault clearance. The results also demonstrate that the proposed method remains effective under various fault and load conditions.
The rapid expansion of voltage source converter-based high voltage DC grids has made DC fault protection a critical research priority, due to low network impedance and the absence of natural current zero crossings. DC fault current limiters have emerged as an effective means of suppressing the rapid rise of fault curre...
M. Mohammadi, Saeed Norouztamar, Hossein Iman-Eini et al.· IEEE Open Journal of Power E...· 0 citations
Driven by the “dual carbon” goals, the large-scale application of renewable power generation, DC distribution networks, and energy storage systems has increasingly highlighted the short-circuit protection challenges in low-voltage DC (LVDC) systems. LVDC faults are characterized by rapidly rising fault currents and the...
In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...
Muhammad Abdul Rauf, Munira Batool, I. Madni· Energies· 0 citations
Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault cu...
Hao-Yu Wang, Chi Zhang, Mafu Zhang et al.· 0 citations