CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC).
Abstract
Quantitative T2* maps have strong potential for biomarker discovery but are limited by long scan times, rendering them impractical in clinical settings. Significant acceleration can be achieved through undersampling in k-space combined with learning-based reconstruction. However, reconstruction artifacts and noise can propagate into downstream T2* fitting, degrading its accuracy. We introduce CUPA-T2*, a framework that explicitly propagates voxel-wise inter-echo uncertainty from stochastic Monte Carlo dropout reconstructions to downstream T2* fitting via covariance-aware sampling. T2* fitting is performed with a heteroscedastic MLP and a correlation-based regularizer that encourages alignment between predicted variance and reconstruction uncertainty. Experiments on accelerated brain MRI data show tissue-dependent behavior: CUPA-T2* achieves competitive overall T2* fitting performance and improves white-matter performance at higher accelerations. Compared with a heteroscedastic baseline, the proposed framework substantially increases alignment between reconstruction uncertainty and predicted T2* variance, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC). CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates.
SL-MOLED provides accurate, repeatable, and artifact-robust quantitative mapping within a substantially reduced acquisition time, offering a promising framework for reliable multi-parametric MRI with potential for clinical translation.
Wei-Kun Chen, Qing Lin, Tai-Shan Kang et al.· Physics in Medicine and Biol...· 0 citations
BACKGROUND/PURPOSE
Simultaneous T1/T2 mapping with hybrid (mixed) sequences has been proposed, but clinical use is limited by long acquisition times. Accelerated reconstruction-parallel imaging (PI; SENSE), compressed sensing (CS), and deep learning (DL)-allows shorter scans but may alter quantitative values and image...
M. Kanamoto, Yuki Matta, Toshiki Tateishi et al.· Magnetic Resonance Imaging· 0 citations
Purpose To determine whether structural MRI information can improve reconstruction of highly accelerated 3D snapshot chemical exchange saturation transfer (CEST) MRI. Methods Fully sampled brain CEST data were retrospectively undersampled at acceleration factors (AFs) of 4, 6, 8, 10, and 12. We compared reconstruction...
E. Mensah, Abrar Faiyaz, G. Schifitto et al.· bioRxiv· 0 citations
BACKGROUND AND OBJECTIVE
Non-contrast coronary magnetic resonance angiography (NC-CMRA) suffers from inherent low spatial resolution, whereas existing deep learning-based super-resolution methods offer no reliability assessment, which hinders their clinical adoption.
METHODS
To bridge this gap, we develop a task-tail...
Fang-Yi Xing, Ning Cao, Xiu-Han Li et al.· Computer Methods and Program...· 0 citations
Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this...
Jing-Ran Xu, Dong Liang, Hai-Rong Zheng et al.· 0 citations
Purpose: To develop and evaluate an anatomy-aware deep learning framework for enhancement of neonatal 64mT T2-weighted MRI that improves anatomical visibility while preserving native ultra-low-field contrast and enabling quantitative structural analysis. Methods: A multitask network, jointly performing image enhancemen...
P. Cawley, A. Uus, K. Colford et al.· medRxiv· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.