Skip to content
Open access

Robust T1ρ, T2, and T2* mapping via spin-locked MOLED with synthetic data-driven deep learning reconstruction

Aug 2026 · Physics in Medicine and Biology · Vol 71 · 0 citations · 55 references
Physics Medicine

TL;DR

SL-MOLED provides accurate, repeatable, and artifact-robust quantitative mapping within a substantially reduced acquisition time, offering a promising framework for reliable multi-parametric MRI with potential for clinical translation.

Abstract

Objective. To address the challenges of rapid and robust quantitative MRI, particularly for T1ρ mapping, by developing and evaluating a novel technique—spin-locked (SL) multiple overlapping echo detachment (SL-MOLED)—for efficient mapping of T1ρ, T2, and T2* relaxation times with reduced sensitivity to B0/B1 inhomogeneities and SL –related banding artifacts. Approach. SL-MOLED integrates SL preparation into the MOLED acquisition framework, enabling simultaneous mapping of T1ρ, T2, T2*, proton density, and estimation of ΔB0 and B1 in approximately 11 s per slice. A synthetic data-driven deep learning reconstruction framework was trained on Bloch-simulated datasets with explicitly modeled banding artifacts, allowing effective mitigation of artifact-related errors. Validation comprised numerical experiments, phantom studies, healthy volunteer experiments, and a preliminary patient evaluation. Reconstruction accuracy was assessed using the structural similarity index measure (SSIM), mean absolute error (MAE), Pearson’s correlation coefficient (r), and Bland–Altman analysis. Short-term within-session stability and 7 d inter-session test–retest repeatability were evaluated separately using ROI-based coefficients of variations. Main results. Numerical experiments showed that networks trained with artifact modeling improved SSIM by 0.1–0.2 and reduced MAE by 2–5 ms for T1ρ, T2, and T2* compared with models trained without artifact modeling, across varying B0/B1 inhomogeneities and SL frequencies. Phantom studies demonstrated good agreement between SL-MOLED reconstructed maps and reference methods for T1ρ, T2, and T2* (r > 0.997, Bland–Altman bias < 3.4%). In vivo experiments confirmed strong correlations with reference maps (r ⩾ 0.976) and good repeatability. In a patient with multiple sclerosis, SL-MOLED detected elevated T1ρ values in lesions relative to normal-appearing white matter, while T2 and T2* showed smaller changes, indicating that each parameter may reflect different underlying pathological features. Significance. SL-MOLED provides accurate, repeatable, and artifact-robust quantitative mapping within a substantially reduced acquisition time (∼11 s per slice), offering a promising framework for reliable multi-parametric MRI with potential for clinical translation.

Read PDF

Similar papers

Preprint Aug 2026

CUPA-T2*: Covariance-Aware Uncertainty Propagation and Alignment for T2* Mapping in Accelerated MRI

CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC).

Gideon N. L. Rouwendaal, Natascha Niessen, H. Eichhorn et al. · 0 citations
Sep 2026

Acceleration-dependent variability in simultaneous T1/T2 mapping with a hybrid (mixed) sequence: a phantom comparison of SENSE, compressed sensing, and deep learning reconstructions.

BACKGROUND/PURPOSE Simultaneous T1/T2 mapping with hybrid (mixed) sequences has been proposed, but clinical use is limited by long acquisition times. Accelerated reconstruction-parallel imaging (PI; SENSE), compressed sensing (CS), and deep learning (DL)-allows shorter scans but may alter quantitative values and image...

M. Kanamoto, Yuki Matta, Toshiki Tateishi et al. · 0 citations
Open access Sep 2026

Anatomically Guided Deep Learning Reconstruction of Accelerated Snapshot CEST MRI

Purpose To determine whether structural MRI information can improve reconstruction of highly accelerated 3D snapshot chemical exchange saturation transfer (CEST) MRI. Methods Fully sampled brain CEST data were retrospectively undersampled at acceleration factors (AFs) of 4, 6, 8, 10, and 12. We compared reconstruction...

E. Mensah, Abrar Faiyaz, G. Schifitto et al. · 0 citations
Sep 2026

Sequential model-based free-water suppression of T1, T2, and proton density maps for synthetic FLAIR and DIR MRI.

Synthetic MRI (SynMRI) enables flexible generation of contrast-weighted images from quantitative T1, T2, and proton density (PD) maps. However, synthetic inversion-recovery (IR) images are often degraded by cerebrospinal fluid (CSF) partial-volume effects (PVE). We developed a sequential model-based framework for suppr...

Tokunori Kimura · 0 citations
Preprint Oct 2026

Quiet, rapid 3D multiparametric mapping using magnetization-prepared zero echo time MRI

Purpose: To introduce and evaluate MuPa-ZTE, a quiet, rapid 3D framework combining native and magnetization-prepared zero echo time (ZTE) acquisitions for multiparametric mapping. Methods: MuPa-ZTE combines steady-state native ZTE with transient-state magnetization-prepared ZTE. Two implementations were evaluated: T2T1...

Alireza Samadifardheris, Shi-Shuai Wang, A. Solana et al. · 0 citations
Open access Sep 2026

Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based Reconstruction

Deep Resolve improved the robustness of automated brain segmentation in accelerated T2-weighted MRI, reducing cross-protocol variability and improving spatial reproducibility, with the largest reduction in reference-relative error in the most acceleration-sensitive pipeline.

J. Lasek, R. Obuchowicz, M. Strzelecki et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.