Deep networks dominate photovoltaic (PV) thermographic fault detection but need large annotated datasets and resist interpretation. We present a lightweight, interpretable infrared workflow combining support-vector-machine (SVM) module/background segmentation from four handcrafted features with an adaptive grid analysis labelling regions as nominal-intensity, high-intensity anomaly or low-intensity anomaly relative to a module-internal reference; the anomaly classes are inspection candidates, not confirmed faults. Evaluation used 21 close-range images of one 20 W module—recorded with the camera’s visible-light edge fusion active, so they are fused infrared/visible frames—and all 596 of a public five-sector UAV dataset. Segmentation against manual masks reached a mean intersection-over-union of 0.64; a feature ablation shows intensity statistics dominate, and an end-to-end Otsu pipeline gives almost the same high-intensity share (4.54% versus 4.50%): the SVM contributes reproducibility—removing the manual segmentation threshold, though not the empirical +48/−60 offsets—not accuracy. High-intensity regions concentrated in the module’s lower half, co-locating with a bus-bar defect known from hardware inspection—suggestive, not validated. The single-module, image-level close-range evaluation is optimistic, and the UAV shares, from a separately trained SVM, illustrate cross-domain application only. Segmentation runs at about 15 images per second on CPU. The method is a relative-intensity thermal screening workflow, not a validated defect-diagnosis or plant-health assessment method, and applies only where acquisition is controlled and the offsets are recalibrated for the target camera and palette.
Vladimír Szomosi, Stanislav Baňački, Július Šimčák et al.· Solar· 0 citations
This paper presents the design and experimental validation of a micro-phasor measurement unit (uPMU) system developed for real-time protection and power quality analysis in low-voltage distribution networks. The proposed architecture integrates a Raspberry Pi-based Central Protection Unit, an AD7606 synchronous analog-to-digital converter for high-speed multi-channel sampling, and a DAC8568 digital-to-analog converter for test and simulation purposes. The system supports hardware time synchronization via the Precision Time Protocol (PTP) and enables both real and simulated grid event measurements. Experimental results confirm the feasibility of achieving up to 200~kSPS sampling per channel, providing the temporal resolution required for sub-cycle fault detection. The long-term objective is to apply artificial intelligence (AI) techniques to predict the next waveform samples and detect deviations that indicate faults or abnormal grid conditions within microseconds.
József Bencsik, Zsolt Čonka· Advances in Science and Tech...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.