Sep 2026· Journal of Functional Morphology and Kinesiology· Vol 11· 0 citations· 29 references
Medicine
TL;DR
The proposed DL-based markerless video system demonstrated high agreement with Tracker for gait speed assessment during the 10-MWT under outdoor non-laboratory conditions, supporting its potential as an accessible approach for gait speed assessment.
Abstract
Background/Objectives: Markerless video-based gait assessment has emerged as a promising alternative to laboratory motion capture systems because it enables objective, low-cost, and accessible mobility assessment. However, evidence supporting the validity of deep learning (DL)-based markerless video systems for gait speed assessment during the 10-meter walk test (10-MWT) in real-world clinical environments remains limited. This study evaluated the concurrent validity of a DL-based markerless video system for estimating gait speed during the 10-MWT under outdoor clinical conditions. Methods: Thirty-two healthy participants from three age groups completed the 10-MWT under comfortable, slow, and fast walking conditions. Gait speed was simultaneously measured using the proposed DL-based markerless video system with the YOLOv11x model and Tracker video analysis software (version 6.3.2). Gait speed was calculated across six consecutive 1 m walking segments. Concurrent validity was evaluated using Pearson’s correlation coefficients and Bland-Altman analysis. Results: Pearson’s correlation coefficients ranged from 0.92 to 0.98 across all six walking segments and walking-speed conditions, indicating very high concurrent validity. Bland-Altman analysis demonstrated good agreement between the proposed system and the reference method, with mean differences close to zero and most observations falling within the 95% limits of agreement. The proposed system maintained high agreement across comfortable, slow, and fast walking conditions while enabling segment-specific gait speed analysis throughout the 10-MWT. Conclusions: The proposed DL-based markerless video system demonstrated high agreement with Tracker for gait speed assessment during the 10-MWT under outdoor non-laboratory conditions, supporting its potential as an accessible approach for gait speed assessment.
Time-domain gait parameters provide important indicators for clinical assessments, but their measurement often requires specialized in-clinic devices. Video provides an accessible alternative for out-of-clinic gait monitoring, but its low frame rate limits its ability of precise gait-event timing. This paper presents a...
Yu-Liang Fu, Yan-Xin Luo, Sidy Ndiaye et al.· Proceedings of the 4th Inter...· 0 citations
Abstract Background Gait impairment is a prevalent sequela of stroke. Although observational gait analysis remains a standard clinical practice for assessing neuromotor impairments in people with stroke, it is prone to subjective bias. Consequently, objective assessment is required to inform effective rehabilitation pr...
Zhexuan Gu, Jiaqi Li, Wen-Bin Zhou et al.· JMIR Rehabilitation and Assi...· 0 citations
Plantar load is an important biomechanical measure in gait analysis, rehabilitation assessment, and human movement evaluation. However, conventional measurement systems, including instrumented insoles and laboratory-based force measurement devices, rely on dedicated sensing hardware and may limit the accessibility of c...
Yan-Mei Jiao, Gan Huang, Xuan Huang et al.· Italian National Conference...· 0 citations
The results demonstrate the potential for single-camera markerless motion capture to produce clinical grade data in a healthy population, thereby improving the accessibility of clinical gait assessments.
C. Vellucci, Emma J. Ratke, Akanksha Guleria et al.· Journal of Biomechanics· 0 citations
Traditional gait analysis systems often suffer from high costs and operational complexity. To address these limitations, this paper proposes a single-view markerless gait analysis method and system for rehabilitation assessment. The system captures sagittal-plane walking videos using a monocular camera and employs Spor...
Ying-Ying Jia, Ai-Hui Wang, Yao Yao et al.· International Conference on...· 0 citations
This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided refe...
Hyungseok Ryu, Pilwon Hur· 0 citations
Related blog posts
Microsoft Research Blog· microsoft.comOct 30, 2026
Evaluating Microsoft Copilot at enterprise scale requires test data that captures the full complexity of real organizations, yet real enterprise data contains sensitive information that cannot be used for evaluation under any circumstances. The post From synthetic enterprise data evaluations to real Microsoft Copilot AI confidence appeared first on Microsoft Research.
Microsoft Research Blog· microsoft.comOct 29, 2026
Host Sowbhagya Suresh shares some of the latest news and cutting-edge research from across Microsoft—from understanding the challenges facing coding agents to uncovering how people use AI at work and improving extended-range weather forecasting. The post Microsoft Research Focus – Edition #97 appeared first on Microsoft Research.