Aug 2026· Journal of Esthetic and Restorative Dentistry· 0 citations· 41 references
Medicine
TL;DR
Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region, and molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness.
Abstract
Objective
To evaluate the effects of pulp chamber depth, tooth type, and intraoral scanner (IOS) on the accuracy of endocrown digital impressions.
Materials And Methods
Standardized endocrown preparations with 2 and 5 mm pulp chamber depths were performed on molar and premolar typodonts. Digital impressions were obtained using three IOSs (Dexis, iTero, and 3Shape). Reference scans were acquired using a laboratory scanner. Accuracy was assessed following best-fit alignment. Cavity base and axial regions were separately evaluated. Data were analyzed using Kruskal-Wallis and Dunn post hoc tests (α = 0.05).
Results
Pulp chamber depth, tooth type, and IOS significantly affected scanning accuracy (p < 0.05). Increasing cavity depth increased deviations at cavity base while reducing deviations at axial region. Premolar preparations with 5 mm depth exhibited the highest cavity base deviations (99.5-107.2 μm). At axial region, iTero demonstrated the lowest deviations (28.2 μm) in 5 mm depth molar preparations. Dexis and iTero showed comparable performance at cavity base.
Conclusions
Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region. Molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness. Deep premolar preparations represented the most challenging condition for accurate digital acquisition.
BACKGROUND
The accuracy of intraoral scanners (IOSs) has been widely reported. However, studies comparing their performance under different clinical conditions are lacking.
OBJECTIVES
The aim of the present study was to compare the trueness and precision of 5 IOSs across 4 anatomically distinct models simulating comm...
A. Polizzi, Pietro Venezia, Sara Serra et al.· Dental and Medical Problems· 0 citations
Background.
Accurate assessment of oral soft tissues is an important task in modern dentistry, particularly in implantology and prosthetic practice. Conventional methods for measuring gingival thickness are invasive and operator-dependent, which limits their use for longitudinal monitoring.
Objective.
To evaluate...
E. K. Khabirov, G. Saleeva, R. Saleev et al.· Medical alphabet· 0 citations
OBJECTIVE
The accuracy of intraoral scanners is commonly described by trueness and precision; however, the extent to which single-tooth crown preparation geometry influences these outcomes across different scanner systems remains unclear. This in vitro study aimed to evaluate trueness and to descriptively assess precis...
Şekibe Hüma Sanioğlu, Fatma Emine Karol, O. Harorlı· Journal of Esthetic and Rest...· 0 citations
Abstract Objective The aim of the study is to evaluate the accuracy (trueness and precision) of two intraoral scanners (IOSs) for measuring post space length and area deviation in root canal-treated teeth with differing canal tapers, using a caliper as the reference standard. Materials and methods Fifteen endodonticall...
Dusit Nantanapiboon, Porawit Kamnoedboon, Chawalid Pianmee et al.· European Journal of Dentistr...· 0 citations
OBJECTIVES
To evaluate the effects of different scanning modes of intraoral scanners (scan-only versus restoration type selected) on STL triangle counts and to assess the influence of STL triangle counts on trueness across different scanner systems.
METHODS
A typodont model with 3 prepared teeth was scanned with 15 s...
Hale Arikan Kalayci, Simge Alıcı, Gülçe Çakmak et al.· E -journal of dentistry· 0 citations
Background: Accurate post-space recording is essential for fabrication of well-fitting custom post-and-core restorations. This study compared conventional polyvinyl siloxane impressions with Trios 3, Medit i700, and Upcera intraoral scanners at 6, 8 and 10 mm post-space depths. Materials and Methods: Twenty-four extrac...
Chiramana Sandeep, Bhanavathu Vijay, Kumar et al.· International Journal of Dru...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.