Skip to content
Open access

Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners.

Aug 2026 · Journal of Esthetic and Restorative Dentistry · 0 citations · 41 references
Medicine

TL;DR

Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region, and molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness.

Abstract

Objective

To evaluate the effects of pulp chamber depth, tooth type, and intraoral scanner (IOS) on the accuracy of endocrown digital impressions.

Materials And Methods

Standardized endocrown preparations with 2 and 5 mm pulp chamber depths were performed on molar and premolar typodonts. Digital impressions were obtained using three IOSs (Dexis, iTero, and 3Shape). Reference scans were acquired using a laboratory scanner. Accuracy was assessed following best-fit alignment. Cavity base and axial regions were separately evaluated. Data were analyzed using Kruskal-Wallis and Dunn post hoc tests (α = 0.05).

Results

Pulp chamber depth, tooth type, and IOS significantly affected scanning accuracy (p < 0.05). Increasing cavity depth increased deviations at cavity base while reducing deviations at axial region. Premolar preparations with 5 mm depth exhibited the highest cavity base deviations (99.5-107.2 μm). At axial region, iTero demonstrated the lowest deviations (28.2 μm) in 5 mm depth molar preparations. Dexis and iTero showed comparable performance at cavity base.

Conclusions

Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region. Molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness. Deep premolar preparations represented the most challenging condition for accurate digital acquisition.

Read PDF

Similar papers

Open access Oct 2026

Trueness and precision of 5 intraoral scanners under different conditions in arches: A 3D comparative in vitro analysis.

BACKGROUND The accuracy of intraoral scanners (IOSs) has been widely reported. However, studies comparing their performance under different clinical conditions are lacking. OBJECTIVES The aim of the present study was to compare the trueness and precision of 5 IOSs across 4 anatomically distinct models simulating comm...

A. Polizzi, Pietro Venezia, Sara Serra et al. · 0 citations
Open access Oct 2026

Factors affecting the accuracy of intraoral scanning in digital morphometric assessment of oral soft tissues

Background. Accurate assessment of oral soft tissues is an important task in modern dentistry, particularly in implantology and prosthetic practice. Conventional methods for measuring gingival thickness are invasive and operator-dependent, which limits their use for longitudinal monitoring. Objective. To evaluate...

E. K. Khabirov, G. Saleeva, R. Saleev et al. · 0 citations
Open access Sep 2026

Effect of Preparation Design on the Trueness and Precision of Intraoral Scanners: A Comparative Analysis Across Two IOS Systems.

OBJECTIVE The accuracy of intraoral scanners is commonly described by trueness and precision; however, the extent to which single-tooth crown preparation geometry influences these outcomes across different scanner systems remains unclear. This in vitro study aimed to evaluate trueness and to descriptively assess precis...

Şekibe Hüma Sanioğlu, Fatma Emine Karol, O. Harorlı · 0 citations
Open access Sep 2026

Root Canal Taper and the Accuracy of Intraoral Scanners for Post Space Measurement: An In Vitro Study

Abstract Objective The aim of the study is to evaluate the accuracy (trueness and precision) of two intraoral scanners (IOSs) for measuring post space length and area deviation in root canal-treated teeth with differing canal tapers, using a caliper as the reference standard. Materials and methods Fifteen endodonticall...

Dusit Nantanapiboon, Porawit Kamnoedboon, Chawalid Pianmee et al. · 0 citations
Open access Sep 2026

STL Triangle Count and Trueness in Prepared Tooth Regions: Effects of Scanner System and Scanning Mode Across Intraoral, Laboratory, and Industrial Scanners.

OBJECTIVES To evaluate the effects of different scanning modes of intraoral scanners (scan-only versus restoration type selected) on STL triangle counts and to assess the influence of STL triangle counts on trueness across different scanner systems. METHODS A typodont model with 3 prepared teeth was scanned with 15 s...

Hale Arikan Kalayci, Simge Alıcı, Gülçe Çakmak et al. · 0 citations
Open access Oct 2026

Comparative Evaluation of Post Space Recordings Obtained Using Conventional Silicone Impressions and Different Intraoral Scanners: An In Vitro Comparative Study

Background: Accurate post-space recording is essential for fabrication of well-fitting custom post-and-core restorations. This study compared conventional polyvinyl siloxane impressions with Trios 3, Medit i700, and Upcera intraoral scanners at 6, 8 and 10 mm post-space depths. Materials and Methods: Twenty-four extrac...

Chiramana Sandeep, Bhanavathu Vijay, Kumar et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.