Skip to content
Preprint

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

Aug 2026 · 0 citations · 29 references
Engineering Computer Science

TL;DR

It is suggested that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation, because accurate registration is a prerequisite for deformable dose accumulation.

Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

View source

Similar papers

Conference Aug 2026

Lesion-robust longitudinal brain CT registration via MR-guided image translation

Experimental results demonstrate that the proposed lesion-robust framework for longitudinal brain CT registration based on MRguided image translation consistently outperforms conventional intensity-based registration methods as well as existing image-translation–assisted strategies in both quantitative metrics and visu...

Zijun Cheng, Hui-Xiang Zhuang, Yue Guan et al. · 0 citations
Open access Sep 2026

Dosimetric Impact of Deformable Image Registration versus Simple Summation in Multi-Fraction HDR Brachytherapy for Cervical Cancer under Standard Protocol

DIR-based dose accumulation resulted in significantly lower HR-CTV dose estimates compared with SS, while dose differences for the bladder and rectum remained minimal, and future research should correlate DIR-based dosimetry with clinical outcomes to support anatomically adaptive brachytherapy.

Chitchaya Suwanraksa, Bheampos Rojkitjanuruk, Tanapat Suwanpan et al. · 0 citations
Sep 2026

High-dose-rate prostate brachytherapy imaging optimization: A motorized sagittal three-dimensional ultrasound acquisition system.

The motorized attachment for SR3D acquisition reduced image variability and improved image quality, and may encourage broader use of sagittal reconstruction in HDR-BT, potentially improving patient outcomes.

David Contella, Chandima Edirisinghe, Kevin Barker et al. · 0 citations
Open access Sep 2026

Real-time tumor tracking for magnetic resonance-guided radiotherapy using label-efficient foundation model adaptation

Background and Purpose: Real-time tumor tracking on cine magnetic resonance imaging (cine-MRI) enables intra-fraction motion management in magnetic resonance-guided radiotherapy. Pipelines often rely on deformable registration or template matching to propagate contours, which can degrade under non-rigid motion and cine...

Amparo S. Betancourt Tarifa, Marcel Verheij, René Monshouwer et al. · 0 citations
Review Open access Sep 2026

Automated quality assurance of rigid brain CT/MR image registration using a 3D convolutional neural network

Abstract Background Accurate CT/MR registration is important in stereotactic brain radiotherapy, where small spatial errors may affect target localization and treatment planning. In many clinical settings, registration quality is still assessed primarily through manual visual inspection. However, time and workflow cons...

Zeinab A. Chahrour, Noura Obeid, Ali El-Zaart et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.