Skip to content
Open access

The reliability and validity of a visual analog scale for rating the single leg squat test

Jul 2026 · PeerJ · Vol 14, pp. e21600 · 0 citations · 59 references
Medicine

TL;DR

Preliminary data indicate that VAS reliably and validly rates SLST in individuals with lower-extremity injuries, allowing calculation of minimal detectable change and minimal detectable difference to support clinical interpretation.

Abstract

Background The single leg squat test (SLST) is commonly used for visual movement assessment in subjects with lower extremity injuries. While current methods utilize ordinal rating categorization, adopting a visual analog scale (VAS) may offer potential advantages. The study aims to determine the intra-rater, inter-rater reliability, and validity of a visual analog scale (VAS) for rating the single leg squat test (SLST) in subjects with lower extremity injuries. Methods 58 subjects with lower extremity injuries participated. Intra-rater reliability was assessed by a physical therapist at 1-week and 2-week intervals. Single session inter-rater reliability was assessed by two physical therapists. A 10 cm VAS was used to measure trunk lateral flexion, hip adduction, and dynamic knee valgus during the SLST. Intra-class correlation coefficients (ICC) assessed intra-rater and inter-rater reliability. Validity was assessed by comparing VAS scores to 2-D kinematic analysis. Results Intra-rater reliability was good at both 1 week (ICC = 0.81–0.92, MDC = 1.2–2.2 cm) and 2 weeks (ICC = 0.77–0.79, MDC = 2.7–3 cm). Inter-rater reliability was good to excellent (ICC = 0.78–0.93, MDD = 1–2.6 cm). The correlation between visual assessment and 2-D kinematic analysis was moderate to good (r = 0.66–0.78). Conclusion Preliminary data indicate that VAS reliably and validly rates SLST in individuals with lower-extremity injuries, allowing calculation of minimal detectable change and minimal detectable difference to support clinical interpretation. The MDC and MDD values established for trunk lateral flexion, hip adduction, and dynamic knee valgus allows clinicians to objectively determine if scores between repeated measurement and two raters are different.

Read PDF

Similar papers

Open access Oct 2026

TP8.1 A Visual Analog Scale for Single-Leg Squat Assessment Demonstrates Reliability in Patients with Hip Pathology

Abstract Introduction Accurate assessment of hip function is critical for guiding rehabilitation in patients with hip pathology. The single leg squat test (SLST) is commonly used to evaluate movement quality in this population. However, standardized SLST scoring methods have yet to be identified, and existing methods r...

Grace Armet, Connor Luck, Ashley E. Disantis et al. · 0 citations
Open access Sep 2026

Reliability, validity, and responsiveness of three seated trunk control assessments used during inpatient spinal cord injury rehabilitation.

STUDY DESIGN Cohort study. OBJECTIVES To investigate the reliability, validity, and responsiveness of the Trunk Control Test (TCT) and two Function in Sitting Tests (FIST) for people with a spinal cord injury (SCI; FIST-SCI and Modified-FIST (mFIST)) during inpatient rehabilitation. SETTING Inpatient Rehabilitation...

Anne E. Palermo, S. Denis, E. Gorgon et al. · 0 citations
Open access Sep 2026

The Reliability and Validity of Active Range of Motion Measurement for Fingers Using Three-Dimensional Motion Analysis

The Fugl–Meyer Assessment (FMA) and Range of Motion (ROM) are well-known measures for evaluating finger motor function. However, the finger FMA has a narrow scoring range, and goniometer ROM measurements lack reliability. Therefore, we investigated ROM measurement using a 3D motion capture system (Ultraleap Stereo IR 1...

Saki Moriguchi, Takashi Takebayashi, J. Arata et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.