This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Abstract
Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts. We propose a deep learning method for motion-resolved 4D CBCT reconstruction from conventional free-breathing scans, without a respiratory signal or explicit projection binning. Our CNN takes free-breathing 3D CBCT projections as input and predicts a static volume at maximum inhalation plus ten displacement vector fields (DVFs) spanning a breathing cycle. The network extends U-Net: the encoder acts on filtered projection stacks, the decoder acts in the volume domain, and skip connections are replaced with non-trainable back-projection functions at multiple resolutions to transfer features between domains. The model is trained on simulated CBCT scans and evaluated on 11 unseen simulated patients and 13 clinical free-breathing scans. Two additional models (60 s and 6 s scans) were evaluated by clinical experts on three and two scans, comparing single phases of our 4D reconstruction to reference 3D SART-TV images for tumor and esophagus visibility. Experts preferred our method for tumor visibility (59% vs. 36% no preference, 5% reference) and esophagus visibility (47% vs. 42%, 11%). On simulated data, image quality matched SART-TV (mean RMSE: -1.19 HU, PSNR: +0.09 dB, SSIM: -0.009) while enabling 4D reconstruction. On clinical scans, our method showed sharper dynamic structures (e.g., diaphragm) and fewer motion streak artifacts than traditional reconstruction. This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Low-Dose Computed Tomography (LDCT) reduces radiation exposure but introduces severe quantum noise and streak artifacts that degrade image quality. To address these challenges, we propose the Physics-Guided Sequential State Space Transformer (PS3T), a projection-domain denoising framework that combines sequential state...
Luella Marcos, Paul S. Babyn, Javad Alirezaie· Signals· 0 citations
A deep learning-based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume can restore CBCT longitudinal coverage with high anatomical fidelity, supporting more reliable deformable registration and adaptive radiotherapy workflows in clinical environments constrained b...
Soyoung Chung, J. Kim, Min-Gyo Chung et al.· Journal of imaging informati...· 0 citations
CAMIT provides an effective trade-off between 2D efficiency and 3D contextual modeling, supporting treatment-day anatomical assessment and adaptive workflow guidance, and is evaluated on an unpaired pelvic CBCT/CT dataset.
Xu Chen, Yun-Kui Pang, J. Lian et al.· Biomedical engineering and p...· 0 citations
BACKGROUND
Respiratory motion and inter-fraction anatomical variations reduce the accuracy of dose delivery in lung cancer radiotherapy. Projection-based tumor tracking methods are limited by anatomical overlap and weak tumor contrast. This study developed a deep learning-based real-time, angle-agnostic tumor tracking...
Qiu-Yi Ye, Xiang-Yu Zhang, Xiang-Jie Tan et al.· Physica medica (Testo stampa...· 0 citations
TLCE-morph, a Tri-Path Lie Convolution Encoder-based learning framework for deformable respiratory motion correction in thoracic PET, achieves the most favorable overall quantitative performance and shows more consistent local structural recovery in representative motion-sensitive regions.
Hui Zhou, Long-Xi He, Si-Yu Wang et al.· Frontiers of Physics· 0 citations
Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have sho...
Jia-Le Shen, Guo-Lin Wang, Chen-Hao Wang et al.· 0 citations