To enhance the seismic damping effect of connected structures under intense seismic activities, this study introduces a novel control system for connected structures. This system strategically places the damping layers at different locations within the main towers to mitigate the violent system response of the connected structure during rare earthquakes. The double-sided damping structure mainly involves arranging damping layers in the towers on both sides of the connected structure. The damping layers use lead-core isolation bearings (LRB), which fully combines the concepts of damping and isolation. It applies isolation technology to the damping system of high-rise structures, and can effectively solve the technical problem of overturning when isolation technology is applied to high-rise buildings in engineering experiments. The structure is modeled using ABAQUS. Models for both single-sided and double-sided damping structures are established and subsequently compared with the seismic resistance structure. This comparison is conducted to analyze the time-history response of layer shear, base reaction force, top-layer acceleration, and interstory drift of various structural models under rare earthquakes. Additionally, shear-drift hysteresis curves of the damping layer are constructed to evaluate the energy dissipation rate of the structure’ s damping layer using an energy analysis method. The results show that both damping structures exhibit superior energy dissipation and damping effects. However, the introduction of an additional damping layer in the double-sided damping structure results in a more obvious damping effect and a higher energy dissipation rate. The risk of overturning due to excessive bending deformation of the superstructure is mitigated by designing the location of the damping layer. However, the control effect of both damping structures on vertical earthquakes is not obvious, and further research is needed.
Efficient and practical seismic control of structures-particularly through isolation systems-remains a significant challenge due to high implementation costs and construction complexity. Moreover, their application in retrofitting existing structures often requires extensive modifications.To address these challenges, t...
Nonlinear velocity dampers (NVDs) embedded in coupling beams may enhance the seismic performance of frame–core tube structures by dissipating energy and limiting structural damage. This study evaluates the seismic performance of a 20-story reinforced concrete (RC) frame–core tube building incorporating NVD-equipped cou...
Shen Liu, Bo Li, Hui Wang et al.· Buildings· 0 citations
Earthquakes produce significant lateral forces on structures, which may lead to excessive displacement, structural
instability, and collapse if proper seismic resistant measures are not adopted. The present study focuses on the comparative
seismic performance evaluation of a G+11 reinforced cement concrete (RCC) buildi...
Utkarsh Mishra, R. Grover· International Journal for Re...· 0 citations
Wind turbines in seismically active regions are increasingly vulnerable to earthquake-induced vibrations due to their growing height and flexibility. Effective vibration control is therefore essential to ensure structural safety and operational reliability. This study examines the performance of a novel compact nonline...
This study investigates the effectiveness of different seismic design strategies in improving the
earthquake resilience of buildings. Motivated by the 2011 Tohoku earthquake in Japan, the research
focuses on three major seismic systems: seismic resistance, seismic damping, and seismic base isolation.
Seismic resistance...
Donggyu Han, Priya Gopalan· American Journal of Student...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.