Skip to content

A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3

Aug 2026 · 0 citations · 18 references
Computer Science

TL;DR

It is suggested that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.

Abstract

Medical image segmentation is essential for clinical workflows such as treatment planning and disease assessment. While specialist tools like TotalSegmentator and MRSegmentator achieve strong performance, they require large annotated datasets for training. Medical foundation models offer a promising alternative through large-scale pretraining that reduces the annotation burden for new tasks, but zero-shot performance remains limited. Parameter-efficient adaptation via Low-Rank Adaptation (LoRA) enables efficient specialization with few trainable parameters, but a key question remains: how many expert-annotated cases are needed to achieve clinically useful segmentation performance? We address this by adapting MedSAM3 with LoRA for five abdominal organs (liver, kidneys, spleen, gallbladder, and pancreas) in CT and MRI using only 1, 2, 5, and 10 annotated cases, evaluating on AMOS22 dataset. With just 10 cases, models achieve performance competitive with specialist systems trained on orders of magnitude more data. Notably, this includes reliable gallbladder segmentation (Dice 0.68 CT, 0.59 MRI) where existing tools fail almost completely (Dice 0.0004), while remaining within 5--10% of MRSegmentator for liver, kidneys, and spleen using over 100 times fewer annotations. Furthermore, external validation on the Whole Heart Segmentation dataset shows that the approach extends to cardiac segmentation, a use case beyond the scope of TotalSegmentator (MRI) and MRSegmentator, achieving competitive left ventricle (LV) performance with only 10 annotated cases. Training requires only3--5,hours per organ on a single GPU, approximately 2--3 times faster than nnU-Net. These findings suggest that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.

View source

Similar papers

Review Jul 2026

Medical image segmentation with optimal learning from limited data and annotations: A comprehensive review

This survey extends beyond traditional and deep learning-based augmentation techniques or deep semi-supervised approaches, by explicitly focusing on medical/clinical imaging modalities, by explicitly focusing on CT, MRI, and X-ray, offering a broader perspective.

Pratiksha Gawas, S. Kamath S. · 0 citations
Jul 2026

Unifying Active Learning and Semi-Supervised Learning for Medical Image Segmentation

RegAL is proposed, a unified active semi-supervised framework governed by a shared topology-aware Pareto optimization that couples sample acquisition with unlabeled data utilization and consistently outperforms state-of-the-art AL, SSL, and active semi-supervised baselines across Dice and boundary-distance metrics unde...

Bahram Jafrasteh, Cheng Wan, Heejong Kim et al. · 0 citations
Dataset Open access Aug 2026

PatchChestCT: A patch-level spatial annotation dataset for nine abnormalities in chest CT

This work introduces a token-aligned annotation scheme that is efficient, scalable, and naturally integrates with modern deep learning architectures like Transformers, and shows that models trained with this scheme achieved higher localization performance than weakly supervised baselines trained on image-level labels a...

Yingtai Li, Hong-Chun Zhang, Meng-Yao Xu et al. · 0 citations
Preprint Aug 2026

How Far from Clinical Deployment? Evaluating the Complete Unsupervised Domain Adaptation Pipeline in Medical Imaging

This study finds that a capable adapted model usually exists, but identifying it without target labels is difficult: the validator-selected models leave a large and structural target performance gap to the best available one, with no evaluated validator consistently reliable.

Yi Xiong, L. Gallée, D. Wolf et al. · 1 citation
Jul 2026

Radiological VQA with Multimodal LLMs: Performance and Insights

The findings reinforce that MLLMs currently serve best as assistive decisionsupport tools rather than autonomous diagnostic agents, and highlight the potential of retrieval-augmented and context-aware strategies for improving clinical reliability and interpretability.

Cristovão Pessoa Cândido, Matheus Alves de Oliveira Lima, C. de Souza Baptista et al. · 0 citations
Aug 2026

SM-FSL: Similarity Guided Multi-Source Few-Shot Learning for Lung Ultrasound Diagnosis.

The Global-Local Multi-Source Domain Network (GLMD-Net) for LUS analysis in data-scarce scenarios is developed, which first employs the proposed Average Nearest Neighbor Set Distance (ANNSD) to prioritize relevant source domains for pre-training and harmonizes multi-source gradient updates.

En-Guang Wang, Juxiang Wu, Shuo Gao et al. · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.