Aug 2026· Restauro archeologico· Vol 34, pp. 66-91· 0 citations· 1 references
Abstract
The study presented here forms part of an ongoing, more detailed research project and represents an initial step toward its broader development. It examines the interactions among structural logic, material degradation, environmental factors, and successive restoration phases, focusing on the cumulative nature of pathologies affecting walls, arches, vaults, and supporting elements. Rather than attributing deterioration to a single cause, the Capitolium is interpreted as a stratified architectural system in which material heterogeneity and post-constructional transformations are closely intertwined. Within this framework, the analysis of deformation patterns and equilibrium mechanisms in both vaulted and trabeated systems allows the identification of structural vulnerabilities while avoiding deterministic interpretations of failure. Particular attention is paid to the ambiguity of damage signatures in archaeological contexts, where seismic and non-seismic processes often overlap and are difficult to distinguish. The research integrates archaeological evidence, historical documentation, and structural analysis, highlighting the need for multi-criteria approaches in archaeoseismological interpretation and supporting an understanding of Roman architectural heritage as a dynamic and evolving system.
The area A is located in the Songliao Basin, and the Lower Cretaceous Jiufotang Formation is the main target layer for oil and gas exploration. Intense The Yanshanian tectonic activity strongly reformed the local strata, resulting in a highly fragmented structural pattern and dense fault development in the area. Relyin...
Kuo Yu· International Journal of Ene...· 0 citations
The historic development of the City of Orenburg dates from the late 19
th
and early 20
th
centuries and includes buildings whose ceramic façades perform both structural and architectural-decorative functions. Deterioration and loss of this material compromise the operational reliability of buildings, underm...
V. Gurieva, Yu. V. Blinkova, D. M. Sagandykov· Vestnik Tomskogo gosudarstve...· 0 citations
The seismic assessment of historical masonry aggregates is particularly challenging as their present configuration typically reflects a complex construction history involving geometrical irregularities, heterogeneous structural systems, and mechanical interaction among adjacent buildings. In this context, an accurate r...
Marco Zucca, P. Crespi, M. Scamardo et al.· The Heritage· 0 citations
This paper presents a case study of a three-level (approximately 10 m deep) basement excavation failure at the Wova development in Phillip, ACT. The development comprises four residential towers over a common basement. During bulk excavation, a localised failure of the perimeter excavation occurred within jointed volca...
The Kharita Formation represents one of the principal Lower Cretaceous clastic reservoirs in the Shushan Basin, Western Desert, Egypt. This study integrates seismic interpretation and petrophysical analysis to evaluate the reservoir characteristics, structural controls, and hydrocarbon potential of the Kharita Formatio...
Mohammad Abdelfattah Sarhan, M. I. Abdel-Fattah, H. Hamdan· Scientific Reports· 0 citations
National Theatre of São João (TNSJ), the main theatre in the city of Porto, was built in 1918. Its architectural design, by architect Marques da Silva, is characterized by a structural system based on traditional load-bearing masonry walls with large granite blocks. In contrast, other architectural elements, such as sl...
A. Velosa, S. Andrejkovičová, F. Rocha· Buildings· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.