Skip to content
Open access

Assessment of refractive error by retinoscopy using fogging lens and cycloplegia in school aged children

Jul 2026 · Russian Ophthalmological Journal · Vol 19, pp. 152-157 · 0 citations · 12 references

TL;DR

The present results confirm that fogging retinoscopy when performed with proper protocols by an experienced clinician, gives accurate results and can be a good alternative to cycloplegic retinoscopy.

Abstract

Purpose . To compare the refractive error measurements obtained through cycloplegic retinoscopy and fogging retinoscopy in school-aged children with myopia and hyperopia. Material and methods . A comparative cross-sectional study was conducted using a non-probability consecutive sampling technique among school-age children. The study analyzed 240 readings in children aged 6 to 15 years, with a mean age of 10.64 ± 2.82 years, including 45% males and 55% females. Visual acuity was measured using a LogMAR chart. Two retinoscopic procedures were performed to assess refractive error: fogging retinoscopy with a high-power plus lens and cycloplegic retinoscopy with 1% cyclopentolate and 0.5% tropicamide. The readings were entered into SPSS version 26.0 and compared after converting them into spherical equivalents (SE) using the Wilcoxon Signed-Rank Test, as preliminary analysis indicated that the data did not follow a normal distribution. Results . Descriptive statistics revealed minimal differences in SE measurements between fogging retinoscopy (mean = -0.41, SD = 5.63) in hyperopes and (mean = -4.8, SD = 3.65) in myopes and cycloplegic retinoscopy (mean = -0.47, SD = 5.64) in hyperopes and (mean = -4.9, SD = 3.69) in myopes. Inferential analysis showed no significant difference between the two methods in low to moderate hyperopes and myopes (p > 0.05) and a significant difference between the two methods in high hyperopes and myopes (p < 0.05). Conclusion . The present results confirm that fogging retinoscopy when performed with proper protocols by an experienced clinician, gives accurate results and can be a good alternative to cycloplegic retinoscopy.

Read PDF

Similar papers

Open access Aug 2026

A To Compare the Accuracy of the Borish Delayed Technique and Cycloplegic Refraction in Determining Refractive Errors among Children Aged 6–18 Years

The Borish delayed technique may be considered an adjunctive approach when cycloplegic refraction is not feasible, but it should not be regarded as interchangeable with cycloplegic refraction on the basis of statistical difference testing alone.

Prakash Chintamani, Anju Singh, Purushottam Naidu Menda et al. · 0 citations
Open access Sep 2026

Self-Reported Visual Clarity and Its Association with Refractive Error and Visual Acuity among Schoolchildren in Kuala Lumpur

Objective: To determine the pattern of self-reported visual clarity across refractive error groups and examine its association with visual acuity among primary schoolchildren in Kuala Lumpur.Material and Methods: This retrospective cross-sectional study analysed the vision screening data from 10 primary schools in Kual...

Siti Nordiana Abd Rahman, Mohd Helmi Abu Yahya, Abdallah Naqaweh et al. · 0 citations
Open access Sep 2026

Effect of fogging lenses on accommodation using an open-view portable wavefront autorefractor

Purpose To investigate the effect of a + 2.00 D fogging lens on accommodative behavior during measurements with an open-view handheld wavefront autorefractor, considering refractive status and fogging duration. Methods Participants underwent six consecutive 10-second measurements per eye using an open-view autorefracto...

Pablo Bargalló, Gonzalo Guerrero, Paula Egido et al. · 0 citations
Open access Sep 2026

Comparison Between Mohindra Retinoscopy and Wet Retinoscopy in Refraction of Infants and Children

Purpose: The purpose of this study was to compare the results of Mohindra near retinoscopy and wet retinoscopy in the refraction of infants and children. Methods: This comparative cross-sectional analytical study included 56 participants, comprising two equal groups of 28 infants and 28 children with refractive errors....

Mousffa Abdul Ghafoor, Afia Tahir, Shahid Noor et al. · 0 citations
Review Sep 2026

Accuracy of intraocular lens power calculation in pediatric aphakia with the Artisan iris-claw lens.

In this cohort, SRK/T showed the least systematic bias with the manufacturer-supplied constant and the lowest observed absolute prediction errors after optimisation, with T2 and EVO 2.0 performing comparably and no individual formula demonstrated statistically significant superiority after correction for multiple compa...

You-Tian Hu, Peyran Fam, H. Fam et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.