Skip to content
Open access

Comparison of a model combining conventional ultrasonography and strain elastography with ACR TI-RADS for reducing unnecessary fine-needle aspiration in solid-predominant partially cystic thyroid nodules: a multicenter study

Oct 2026 · Gland surgery · Vol 15 · 0 citations · 27 references
Medicine

Abstract

Background Solid-predominant partially cystic thyroid nodules (PCTNs) present challenges for malignancy risk stratification and fine-needle aspiration (FNA) decision-making. This study aimed to compare a multiparametric ultrasound model integrating conventional ultrasound and strain elastography with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) management strategy for reducing unnecessary FNA in solid-predominant PCTNs. Methods This multicenter retrospective study included solid-predominant PCTNs evaluated at three tertiary referral hospitals between October 2018 and May 2024. A total of 375 nodules were included, with 264 assigned to the training cohort and 111 to the validation cohort. Two predictive models were constructed: Model 1 incorporated maximum nodule diameter and conventional ultrasound features, and Model 2 additionally included elastography. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis. Results Among the 375 included nodules, 198 (52.8%) were malignant. In the validation cohort, the AUCs were 0.63 [95% confidence interval (CI): 0.54–0.73] for the ACR TI-RADS management strategy, 0.80 (95% CI: 0.72–0.88) for Model 1, and 0.86 (95% CI: 0.78–0.93) for Model 2. Using the continuous ACR TI-RADS score, Model 2 achieved a higher AUC (0.86 vs. 0.74; paired DeLong P=0.02). Elastographic stiffness was the strongest predictor of malignancy in Model 2 [odds ratio (OR), 10.53; 95% CI: 3.65–30.38; P<0.001]. At a threshold probability of 0.62 and relative to the hypothetical strategy of performing FNA for all nodules, Model 2 could potentially avoid 56% of FNAs while missing 27% of malignant nodules, compared with 41% and 27%, respectively, under the ACR TI-RADS management strategy. Conclusions The combination of conventional ultrasound features and strain elastography outperformed the ACR TI-RADS system for FNA triage in solid-predominant PCTNs and may help reduce unnecessary FNA procedures.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.