Skip to content

Enhancing Cone-Beam Computed Tomography Image Quality Using Deep Learning-based Super-Resolution

Nov 2026 · Dentomaxillofacial Radiology
Advanced Image Processing Techniques

Abstract

Objectives

To develop deep learning super-resolution (SR) models for enhancing cone-beam computed tomography (CBCT).

Methods

Seventy CBCT volumes (75 µm voxel size) served as references. Paired low-resolution (LR) volumes (300 µm) were simulated using physics-based degradation. Four architectures were each trained with three loss configurations (L1; L1+edge; L1+edge+perceptual): Swin Transformer for Image Restoration (SwinIR), Hybrid Attention Transformer (HAT), Hybrid Multi-Axis Aggregation Network (HMA-Net), and Dense-Residual-Connected Transformer (DRCT). Performance was assessed with peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). Three dentists ranked the 12 configurations in 28 sets using blinded forced-choice pairwise comparisons. Correlations of metrics and expert ranks were assessed using Spearman correlation.

Results

All configurations outperformed LR input and bicubic interpolation on every metric (p < 0.05). HMA-Net trained with L1+edge+perceptual loss performed best on LPIPS (0.216) and DISTS (0.186). HAT with L1 loss achieved the highest PSNR (28.79 dB) and SSIM (0.820). Experts ranked DRCT and HAT with L1 loss, and DRCT with L1+edge loss, as the best configurations (p < 0.001 versus others). Expert rank correlated moderately only with PSNR (rho = -0.65) and SSIM (rho = -0.60; both p < 0.05).

Conclusions

Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance. ADVANCES IN KNOWLEDGE: Transformer-based super-resolution improved expert-perceived detail of simulated low-resolution in vivo CBCT scans without additional radiation dose, supporting further validation on directly acquired low-resolution scans.

View source

Similar papers

#computer vision Review Sep 2017

Agile Software Development Methods: Review and Analysis

This publication proposes a definition and a classification of agile software development approaches and analyses ten software development methods that can be characterized as being "agile" against the defined criterion.

P. Abrahamsson, O. Salo, Jussi Ronkainen et al. · 727 citations · ⚡54
#computer vision Jun 2008

The impact of agile practices on communication in software development

The study shows that agile practices improve both informal and formal communication, but indicates that, in larger development situations involving multiple external stakeholders, a mismatch of adequate communication mechanisms can sometimes even hinder the communication.

M. Pikkarainen, Jukka Haikara, O. Salo et al. · 401 citations · ⚡48
#machine learning Review Open access Oct 2014

Software development in startup companies: A systematic mapping study

The results indicate that software engineering work practices are chosen opportunistically, adapted and configured to provide value under the constrains imposed by the startup context.

Nicolò Paternoster, Carmine Giardino, M. Unterkalmsteiner et al. · 394 citations · ⚡54

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.