Jul 2026· Clinical Research in Cardiology· 0 citations· 27 references
Medicine
TL;DR
This single-center study supports the use of sex- and segment-specific reference values for standardized T1-MOLLI and T2-GraSE mapping at 3 T to facilitate the characterization of myocardial pathologies, while age seems to be negligible.
Abstract
Aims
Accurate age- and sex-specific T1 and T2 reference values are critical for differentiating myocardial pathologies, yet existing data are inconsistent due to methodological variability. This study proposes standardized T1 and T2 mapping protocols with clinically feasible breath-hold durations and reports site-, sequence-, age-, sex-, and segment-specific reference values.
Methods
AND
Results
This prospective, single-center study enrolled 183 healthy Caucasian subjects (median age 34 y [IQR 22, 50], range 11-70 y, 98 females) who underwent both global and AHA segment-based native T1 and T2 mapping at 3 T. T1 was assessed using Modified Look-Locker Inversion-Recovery sequence, MOLLI 5s(3s)3s, while T2 was performed using a gradient spin-echo (GraSE) protocol with echo-planar-imaging readout. Assessment of T1 and T2 relaxation times was highly reproducible, with low intra- and interobserver, scan-rescan, and test-retest variability. Mean global T1 was 1238 ± 28 ms, and median global T2 was 45.4 ms [44.3, 46.8]. T1 was significantly higher in women than in men (1245 ± 28 ms vs. 1230 ± 7 ms, P < 0.001), while T2 did not differ significantly (45.3 ms [44.2, 46.6] vs. 45.6 ± 2.2 ms, P = 0.453). Segmental analysis showed higher T1 and T2 values in the septum than in the lateral wall (P < 0.005). Subtle associations of age with T1 and T2 were observed.
Conclusion
This single-center study supports the use of sex- and segment-specific reference values for standardized T1-MOLLI and T2-GraSE mapping at 3 T to facilitate the characterization of myocardial pathologies, while age seems to be negligible.
Background The clinical utility of quantitative T1 mapping in cardiac MRI is constrained by variability across acquisition protocols, and a comprehensive comparison between commonly used sequences remains unavailable. Purpose To provide a full range of cardiac MRI native T1 and extracellular volume fraction (ECV) value...
Hua-Ying Zhang, C. Cui, Wen-Li Zhou et al.· Radiology· 0 citations
Background This study presents reference ranges for cardiovascular magnetic resonance (CMR)-derived myocardial strain from the Healthy Hearts Consortium, while evaluating variations by demographic characteristics (age, sex, and ethnicity) and technical factors (scanner vendor, magnetic field strength). We derived refer...
J. Salatzki, D. Condurache, R. Roy et al.· medRxiv· 0 citations
Among cardiac T1 mapping techniques, Modified Look-Locker Inversion recovery (MOLLI) 5(3)3 and Saturation Method using Adaptive Recovery Times (SMART1Map) are widely used, yet their comparative behavior across age groups and their sensitivity to clinical and cardiac functional parameters remain insufficiently character...
Mariem Dali, Narjes Benameur, H. Hafsi et al.· The Egyptian Journal of Radi...· 0 citations
Quantitative myocardial T1 mapping is an established technique in cardiovascular magnetic resonance (CMR). However, conventional T1 mapping requires relatively long breath-holds (BH), which may lead to breathing artifacts and reduced image quality in patients with limited BH capacity. The T1 fast low angle shot (T1FLAS...
L. Röwer, Yara Hussen-Demir, P. E. Verde et al.· BMC Cardiovascular Disorders· 0 citations
PURPOSE
Hepatic MRI T1 relaxation time is a putative measure of fibrosis and inflammation but may be confounded by hepatic fat. This study evaluated a chemical shift-encoded Modified Look-Locker Inversion Recovery (CSE-MOLLI) technique for simultaneous water-specific T1 (water-T1), proton density fat fraction (PDFF), a...
Amol Pednekar, Joshua S. Greer, Pradipta Debnath et al.· Abdominal Radiology· 0 citations
The septal ROI method yielded T1 measurements similar at the group level to those obtained with whole-myocardium contouring, with no statistically significant difference in prognostic performance, while requiring less extensive image analysis.
Yi Zhao, Hong-Rui Yang, Meng-Qiu Zhang et al.· Journal of Visualized Experi...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.