A strong partitioned time-integration algorithm for coupled 0D–1D cardiovascular models: application to pulmonary artery banding
Abstract
Abstract The principal result is a strong partitioned time-integration algorithm for a class of coupled dynamical models whose subsystems are advanced by independent time integrators and interact through a finite-dimensional vector of interface variables. Each coupling trial recomputes both subsystem trajectories from the converged state at tn, evaluates the interface data at the internal stage times required by each solver, and advances the complete coupled state only after convergence of the interface fixed point. The general construction permits different discretisations for subsystems with different mathematical structure, while its applicability requires well-posed subsystem propagators and a locally convergent relaxed interface iteration. The algorithm is specialised to a closed-loop zero-dimensional–one-dimensional cardiovascular model. Cardiac chambers are described by 0D inertial-resistive pressure-volume relations with time-dependent elastance, the valves by a smooth damped second-order model, the major vessels by 1D hyperbolic balance laws, and the peripheral circulations by two-compliance blocks. The chamber-valve differential-algebraic system is integrated by a one-stage, two-derivative, third-order Obreshkov formula. The vascular discretisation combines MUSCL reconstruction, the local Rusanov flux, second-order compatibility conditions, and an IMEX–SSP2(2, 2, 2) method. A short banded pulmonary artery segment is represented by a passive dynamic interface. Dynamic relaxation reduces the mean number of subsystem trials from 8.71 to 2.58 and the maximum from 37 to 5, corresponding to a reduction of approximately 70% in this direct cost measure. Component tests verify the automatic differentiation, compatibility conditions, finite-volume and IMEX discretisations, band solver, and volume balance. Adult and neonatal four-chamber calculations are compared with published physiological ranges. A neonatal three-chamber model then quantifies the dependence of pulmonary-to-systemic flow, distal pulmonary pressure, systemic cardiac index, proximal loading, and dynamic pressure loss on the relative band diameter. Patient-specific use requires clinical calibration and additional representation of oxygen transport and congenital shunts.