A-147 Performance of an IFCC-Compliant Immunoturbidimetric HbA1c Assay: A Study of Consistency with the Gold Standard

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Glycated hemoglobin (HbA1c) reflects average blood glucose over 2–3 months and is the gold standard for diabetes diagnosis and monitoring, as recommended by the American Diabetes Association. High-performance liquid chromatography (HPLC) is the gold standard for HbA1c but is slow and costly. Traditional immunoturbidimetric assays suffer from complexity and instability. This study develops an oligomeric antibody-based immunoturbidimetric method to achieve HPLC-comparable accuracy with enhanced stability, offering a practical clinical alternative. This study evaluated the Zybio HbA1c immunoturbidimetric kit (oligomeric antibody technology) against the HPLC gold standard (Arkray HA-8180) using 194 clinical samples. Regression analysis assessed consistency, and analytical performance was compared with traditional immunoturbidimetric assays. An immunoturbidimetric assay for HbA1c detection was constructed using oligomerized anti-glycated hemoglobin antibodies (Figure 1A). The consistency between the Zybio’s HbA1c kit and HPLC an R2 value of 0.9928, as shown in Figure 1B.Within the linear range of?[3.6%,14%][3.6%,14%], the regression equatio was?Y=1.0118X+0.1999Y=1.0118X+0.1999, with a correlation coefficient?r=0.9979r=0.9979, exceeding the required threshold of 0.975,(Figure 1C,D). HbA1c kit eliminated the polyclonal antibody component used in traditional immunoturbidimetric assays, leading to a significant performance improvement over conventional assay method. The traditional method exhibited a low-end repeatability CV = 7%, whereas HbA1c kit demonstrated a repeatability CV < 2.5%(Figure 1E,F). Moreover, the relative deviation of Zybio’s HbA1c reagent after 30 days of in-use stability was < 5%, while the deviation for the traditional method exceeded 7% after just 15 days of in-use stability(Figure 1G,H). This study applies oligomeric antibody technology to improve the immunoturbidimetric detection of HbA1c, addressing the stability and repeatability limitations of traditional methods. Additionally, in clinical practice, the detection results of Zybio’s HbA1c reagent kit demonstrated excellent consistency with those obtained by HPLC.The detection results of Zybio’s HbA1c kit have also received continuous certification from the IFCC. The evaluated HbA1c kit demonstrates reliable performance in clinical agreement, stability, and repeatability, making it suitable for routine diagnostics. Its automated, high-speed platform effectively meets clinical needs for accuracy, efficiency, and cost-effectiveness.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.