Image quality assessment of 40-keV virtual monoenergetic reconstruction in low-contrast lower-extremity spectral CT angiography.
Abstract
INTRODUCTION Lower-extremity CT angiography (CTA) is widely used for the assessment of peripheral arterial disease. Reducing iodinated contrast medium is desirable, particularly in patients with impaired renal function. This study evaluated the impact of 40-keV virtual monoenergetic images (VMI) on image quality in low-contrast lower-extremity spectral CTA.
Methods
In this retrospective single-center study, 60 patients who underwent lower-extremity spectral CTA with 40 mL of iodinated contrast medium were included. Conventional reconstructions and 40-keV VMI were compared regarding vascular attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine concentration, and subjective image quality across predefined arterial segments. Qualitative image quality was independently assessed by two readers using a 5-point Likert scale.
Results
Compared with conventional reconstructions, 40-keV VMI significantly increased vascular attenuation, SNR, and CNR across all arterial segments (all p < 0.001). Subjective ratings for vessel contrast, vessel sharpness, overall image quality, and diagnostic confidence were significantly higher with VMI for both readers across all evaluated arterial segments (all p < 0.05). Iodine concentration decreased progressively from proximal to distal arterial segments, whereas the CNR advantage of VMI remained preserved throughout the arterial tree.
Conclusion
Forty-keV virtual monoenergetic reconstruction significantly improves quantitative and qualitative image-quality parameters in low-contrast lower-extremity spectral CTA compared with conventional reconstructions. These findings suggest that low-keV VMI may improve image-quality characteristics in reduced-contrast CTA protocols, particularly in distal arterial segments. IMPLICATIONS FOR PRACTICE Low-keV virtual monoenergetic reconstruction may support reduced-contrast lower-extremity CTA protocols by improving image quality without increasing contrast medium volume. This approach may be particularly valuable for patients in whom minimizing iodinated contrast medium exposure is desirable.