Skip to content
Case report Open access

3D Intracardiac Echocardiography-Guided Mitral M-TEER for a Challenging Medial P3 Flail in Patient With Esophagectomy.

Oct 2026 · JACC Case Reports · pp. 111340 · 0 citations · 4 references
Medicine

Abstract

Background

Transesophageal echocardiography (TEE) is the standard imaging modality for mitral transcatheter edge-to-edge repair (M-TEER). When TEE is contraindicated, 3-dimensional intracardiac echocardiography (ICE) may provide an alternative; however, published experience remains limited and has predominantly involved central A2/P2 pathology. CASE SUMMARY A 69-year-old man with severe degenerative MR from a medial P3 flail and prior esophagectomy underwent M-TEER exclusively under 2D/3D ICE guidance. ICE facilitated transseptal puncture, guide positioning, clip orientation, leaflet grasping, and assessment of residual MR and transmitral gradient. One MitraClip XTW was implanted at A3/P3, reducing MR from severe to mild with a mean gradient of 2 mm Hg. He was discharged the following day without complications.

Discussion

This case demonstrates that comprehensive ICE guidance can extend M-TEER beyond the commonly reported A2/P2 position to challenging medial anatomy. TAKE-HOME MESSAGE Comprehensive 2D and 3D ICE can enable safe and effective M-TEER of challenging A3-P3 pathology when TEE is contraindicated or not feasible.