Skip to content
Open access

Diagnostic Performance and Safety of Endoscopic Ultrasound-Guided Fine-Needle Biopsy (EUS-FNB) Under Conscious Sedation for Small Solid Pancreatic Lesions (<20 mm): A Retrospective Cohort Study

Nov 2026 · Journal of Clinical Medicine · Vol 15, pp. 8522 · 0 citations · 33 references

TL;DR

EUS-FNB under conscious sedation appears feasible, with high diagnostic yield and a low rate of adverse events, in consecutive eligible patients with small SPLs, including sub-centimetric targets, and these findings support a pragmatic real-life workflow.

Abstract

Background/Objectives: The diagnostic evaluation of small (<20 mm) solid pancreatic lesions (SPLs) remains technically challenging, and most available EUS-FNB data derive from cohorts performed under deep sedation or heterogeneous sedation protocols. This study evaluated the diagnostic performance, feasibility, and safety of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed under standard conscious sedation in consecutive eligible patients with SPLs < 20 mm. Methods: This was a single-center retrospective analysis of a prospectively maintained database including 114 patients with SPLs < 20 mm who underwent EUS-FNB under conscious sedation between January 2021 and December 2024. Procedural characteristics, histologic adequacy, diagnostic accuracy, repeated procedures, and adverse events were collected. Index diagnostic accuracy was calculated on completed index procedures; procedures aborted because of intolerance were analyzed as sedation failures and included in the safety and cumulative analyses. Variables associated with tissue core adequacy were assessed in an exploratory univariate analysis. Results: The mean target lesion size was 14.2 ± 4.3 mm, and 31 lesions (27.2%) were sub-centimetric (<10 mm). A 22-gauge needle was used in 98.2% of cases, a Franseen-tip needle in 80.4%, and at least two passes were performed in 87.5%. Among the 112 completed index procedures, histologic adequacy was 93.8% (105/112, 95% CI 87.7–96.9) and diagnostic accuracy was 91.1% (102/112; 95% CI 84.3–95.1), increasing to a cumulative accuracy of 97.4% (111/114) after targeted repeat procedures. Index accuracy was 93.5% (29/31) for lesions < 10 mm and 90.1% (73/81) for lesions of 10–19 mm (p = 0.724). Counting the three repeat procedures performed with anesthesiology support as failures of the conscious sedation pathway, cumulative accuracy under conscious sedation alone was 94.7% (108/114). Sensitivity, specificity, PPV and NPV of the index EUS-FNB for malignancy were 92.5%, 100%, 100% and 73.1%, respectively. No severe intraprocedural adverse events occurred; two index procedures (1.8%) were aborted because of intolerance under conscious sedation and required anesthesiology support, and two mild, self-limiting cases of acute pancreatitis (1.8%) occurred after the procedure. In the exploratory analysis, performing at least two needle passes was the only variable associated with sample adequacy (p = 0.041), although this finding was based on only seven inadequate samples. Conclusions: EUS-FNB under conscious sedation appears feasible, with high diagnostic yield and a low rate of adverse events, in consecutive eligible patients with small SPLs, including sub-centimetric targets. These findings support a pragmatic real-life workflow based on careful patient selection, adequate monitoring, modern FNB needles, macroscopic core assessment, and consideration of at least two passes whenever feasible (a hypothesis-generating finding), with ROSE or anesthesiologist support reserved for selected unresolved or poorly tolerated cases. Prospective comparative studies are needed before concluding equivalence with propofol-based deep sedation or systematic anesthesiologist-directed care.

Read PDF

Similar papers

Review Open access Oct 2026

EUS-fine needle aspiration for computed tomography-detected retroperitoneal nonmass lesions after failed or infeasible percutaneous biopsy: A 2-center comparative study

Retroperitoneal nonmass lesions (NMLs) present significant diagnostic challenges due to their ill-defined margins and subtle radiographic features. This 2-center study evaluated the diagnostic efficacy and safety of EUS-fine needle aspiration (FNA) for NMLs following failed or infeasible percutaneous biopsy, compar...

Wei-Lu Chai, Rong Zhang, Li Yu et al. · 0 citations
Open access Nov 2026

Diagnostic efficacy of percutaneous computed tomography-guided needle biopsy of suspected malignant pancreatic lesions using a large needle: a retrospective cohort study from a single academic institution

This study aims to assess the diagnostic yield, accuracy, and safety of percutaneous computed tomography-guided needle biopsy for suspected malignant pancreatic lesions diagnosed based on preoperative CT or MRI scans, conducted in a large patient cohort using large-bore needles. Additionally, it seeks to identify t...

Meng Wang, Shuai Li, Ke-Pu Du et al. · 0 citations
Review Oct 2026

Comparison of diagnostic performance of 19-gauge versus 22-gauge fine-needle biopsy needles for endoscopic ultrasound-guided liver biopsy: a systematic review and meta-analysis.

Studies have compared 19-gauge (19G) and 22G needles for endoscopic ultrasound-guided liver biopsy (EUS-LB) and reported variable results. We conducted a meta-analysis to compare the outcomes of EUS-LB with 19G vs. 22G needles. We reviewed several databases from inception to 19 October 2025. Outcomes of interest were d...

Aamir Saeed, J. Perry, J. Kothadia et al. · 0 citations
Review Open access Oct 2026

췌장고형종양의 초음파내시경 유도하 조직 채취

Advances in needle design, sampling techniques, on-site evaluation, antibiotic considerations, and complication management in endoscopic ultrasound–guided tissue sampling of pancreatic solid tumors are summarized.

우진 Woo Jin 김 Kim, 성용 Sung Yong 한 Han · 0 citations
Open access Sep 2026

The Role of Fine-Needle Aspiration Biopsy and Sonographic Stratification in Surgical Decision-Making for Pediatric Thyroid Nodules: Experience from an Ambulatory Surgery Center

Introduction: Pediatric nodular thyroid disease is associated with an elevated probability of malignant transformation (20% to 26%), necessitating precise preoperative diagnostic triage (1). International consensus guidelines establish ultrasound-based risk stratification using the Thyroid Imaging Reporting and Data Sy...

Shahkarim Ibragimov, Zarip Mukhamedov · 0 citations
Open access Sep 2026

Multimodal planning of vacuum-assisted fine-needle aspiration biopsy for focal liver lesions: A single-center comparative diagnostic study

The rate of informative cytological samples was higher with v-FNAB than with standard FNAB, and the proportion of non-informative aspirates was lower, and v-FNAB may be considered for inclusion in the diagnostic algorithm for patients with focal liver lesions.

A. Tagil, A. V. Borsukov · 0 citations