Solvent-Based Desalination for Ultra-Saline Produced Water Treatment and Reuse
Abstract
This study presents the development, pilot-scale validation, and performance assessment of a membrane- free solvent extraction desalination technology for ultra-saline produced water from oil and gas operations. Conventional membrane systems face severe limitations on hypersaline wastewaters above seawater salinity due to fouling, scaling, osmotic pressure, and low recovery. The objective is to evaluate a solvent- based process capable of desalinating feedwaters from 35,000 to over 200,000 mg/L total dissolved solids (TDS) at near-ambient pressure using low-grade thermal energy. The study includes field validation at the Brackish Groundwater National Desalination Research Facility (BGNDRF) in Alamogordo, New Mexico. Additional objectives include identifying mechanical limitations in the field, validating design improvements, and establishing scalability pathways. The process uses a temperature-driven solvent extraction mechanism that transfers water from saline feed into a proprietary organic solvent while rejecting dissolved salts, operating without membranes and below 5 psig. At 15 to 45°C, water is absorbed into the solvent; the mixture is heated to 50 to 90°C, separating purified water from solvent, which is recycled in a closed loop. A pilot unit with extraction and regeneration vessels, heating and cooling loops, dual plate heat exchangers, circulation pumps, and PLC-based monitoring was field-tested at BGNDRF under continuous flow. Feedwater was primarily synthetic seawater-type brine up to 45,000 mg/L TDS, with supplementary laboratory testing on produced water exceeding 150,000 mg/L TDS. Streams were sampled for TDS, conductivity, pH, ion concentrations, salt rejection, and solvent carryover. Laboratory studies investigated performance deviations and validated extraction vessel design improvements. Laboratory bench testing achieved 95% or greater salt rejection on synthetic seawater feed at 35,000 mg/L TDS, producing polished water at 310 to 418 mg/L TDS. Single-stage water recovery averaged 97.3%, exceeding typical reverse osmosis recovery at comparable salinities. Solvent carryover was reduced to nondetectable levels via integrated polishing. Field testing demonstrated sustained desalination over 16 operating days with salt rejection above 90%. Long-duration testing confirmed solvent stability under repeated thermal cycling. Energy analysis showed low electrical demand and compatibility with thermal sources below 70°C, supporting waste heat integration. The results show a viable approach for ultra-saline produced water where membrane systems are impractical.