B-302 Body Fluids as Complex Analytical Metrices: Challenges in Validation and Analytical Performance of Automated Biochemistry Analyzers
Abstract
Analysis of body fluids in clinical laboratories provides important information for diagnostic and therapeutic decision-making. However, evaluating analytical performance in body fluids remains challenging, as these complex matrices are rarely validated by manufacturers during product development. In this context, clinical laboratories must assess analytical performance using these matrices, a process essential for determining method suitability and ensuring patient safety. This study aimed to evaluate the analytical performance of the XT3400 analyzer (Ortho Diagnostics) for measuring of amylase, lactate dehydrogenase (LDH), glucose, and total protein in body fluid samples, as well as to describe the challenges associated with their validation. Three tests were performed: (i) precision, (ii) comparison, and (iii) linearity to assess analytical performance. For precision, two levels of routine commercial controls were processed in quintuplicate over five days. The acceptance criteria applied were one-quarter and one-third of the total allowable error (TAE) to evaluate repeatability and reproducibility, respectively. Comparison was performed using 40 samples processed on the Vitros 5.1 analyzer (reference) and on the XT3400 analyzer (test), both from Ortho Diagnostics. The acceptance criteria were a correlation coefficient of r² > 0.95 and/or agreement of results evaluated in accordance with the TAE. For linearity, two samples (high and low concentration) were selected and mixed to obtain four intermediate dilutions (20%, 40%, 60%, and 80%). All six levels were processed in 12 replicates. The acceptance criteria were r²>0.99 and a difference < 1/2 TAE. All data were analyzed using the statistical software EP Evaluator software, version 12.4 (Data Innovations; Burlington, VT). The TAE used in the analyses was obtained from the ControlLab program (a Brazilian external quality assessment and proficiency testing program). Imprecision analysis demonstrated coefficients of variation (CV) ranging from 0.4% to 3.4%, meeting the predefined acceptance criteria for all analytes. Method comparison showed excellent agreement between systems, with correlation coefficients of r² > 0.99 and observed differences remaining within the TAE limits, although the XT3400 analyzer yielded higher values for amylase and total protein compared with the Vitros 5.1. Linearity assessment demonstrated satisfactory performance, with all analytes achieving r² > 0.99 across the evaluated concentration ranges, despite the limited range of samples. The analytical performance results demonstrated that validation of body fluid measurements using the XT3400 analyzer met the established acceptance criteria for precision, method comparison, and linearity. Nevertheless, the limitations identified in this study, particularly the restricted availability of samples with clinically relevant concentrations, sufficient volume for parallel analysis, and the lack of reference interval values for most body fluids, represent practical challenges. Most body fluids do not have reference intervals described by the manufacturer, which impacts some validation tests. Therefore, it is important to emphasize the need to interpret routine patient results in comparison with serum values from the same patient to ensure proper clinical interpretation for these matrices. Accordingly, careful experimental design and optimized sample management strategies are essential to ensure robust and reliable validation outcomes, ultimately supporting safer clinical interpretation of body fluid results in routine laboratory practices.