Skip to content

Automated Detection of Clinically Significant Mitral Regurgitation from Single-View B-mode Echocardiography Using Deep Learning.

Jul 2026 · Journal of the American Society of Echocardiography · 0 citations
Medicine

TL;DR

MitralVision reliably distinguishes clinically significant MR using single-view B-mode echocardiography without Doppler input for model inference and may support more standardized MR screening.

Abstract

INTRODUCTION Mitral regurgitation (MR) is one of the most prevalent valvular heart diseases, and its diagnosis traditionally relies on Doppler echocardiography, which is subject to significant variability and technical challenges. We developed and externally validated MitralVision, a deep learning model for automated classification of clinically significant MR using single-view, B-mode echocardiographic loops.

Methods

MitralVision, a deep neural network, was trained on 28,487 apical four-chamber (A4C) B-mode echocardiographic cine loops from 11,244 studies across 20 U.S. states. The model was designed to differentiate clinically significant (moderate/severe) from non-significant (none/trace/mild) MR using grayscale cine loops without Doppler input. External validation was performed on 629 studies from 26 independent clinical sites using the original clinical interpretation as the reference standard. A separate board-certified Level III echocardiographer independently re-graded all external validation studies to assess interobserver variability.

Results

On external validation, MitralVision achieved an AUROC of 0.91, sensitivity 82.1%, specificity 84.3%, negative predictive value 91.6%, and positive predictive value of 69.3%, compared with the original clinical read. Interobserver agreement between the original clinical read and the additional expert reader was 75.2% for clinically significant MR, with exact agreement across five MR grades of 35.5%. When benchmarking the additional expert reader's interpretation, model AUROC was 0.89. The model demonstrated excellent calibration (Brier score 0.12; expected calibration error 0.03).

Conclusions

MitralVision reliably distinguishes clinically significant MR using single-view B-mode echocardiography without Doppler input for model inference and may support more standardized MR screening. This streamlined AI-based approach offers reproducible MR assessment and may be compatible with future workflow implementation in high-throughput or resource-limited settings.

View source

Similar papers

Aug 2026

Beyond Doppler: Scalable AI Detection of LVOT Obstruction in HCM.

BACKGROUND Accurate assessment of left ventricular outflow tract (LVOT) gradients is critical for hypertrophic cardiomyopathy management, yet Doppler-based measurements are technically demanding and require expertise. The objective of this work was to develop a multi-view deep learning model capable of classifying LVOT...

O. Crystal, J. Farina, I. Scalia et al. · 0 citations
Open access Jul 2026

Comprehensive Echocardiography Interpretation Using Video and Multiview Vision-Language AI.

A multiview video-language framework improved report retrieval compared with conventional image-based approaches and support the utility of video-based, multiview representation learning for echocardiographic report retrieval.

R. Takizawa, Chiemi Yamazaki, S. Kodera et al. · 0 citations
Open access Jul 2026

BackMix-Enhanced Semi-Supervised Learning for Automated Detection of Aortic Stenosis from Transthoracic Echocardiographic Images

The proposed anatomically guided BackMix augmentation combined with semi-supervised ensemble learning can improve classification accuracy, robustness, and interpretability in echocardiographic analysis under limited annotation conditions, offering a promising approach for automated AS assessment across independent clin...

Fatima Ezzahra Elkouahy, Badreddine Labakoum, H. Ouahid et al. · 0 citations
Open access 2026

ROI-Guided Echocardiographic Image Analysis and Case Aggregation for Differentiating Atrial and Ventricular Septal Defects

This study implemented strict subject-disjoint partitioning to eliminate data leakage, and simultaneously introduced cross-frame case aggregation to emulate the multi-frame visual synthesis process of expert echocardiographers, suggesting that the proposed workflow has the potential to serve as an adjunctive tool for s...

Tao Zhang, Peipei Zhang, Qing-Yuan Zhang et al. · 0 citations
Open access Aug 2026

Dual-flow convolutional neural network for automatic measurement of left ventricular ejection fraction and global longitudinal strain in echocardiography

Echo-DFCNN achieves simultaneous and precise assessment of LVEF and GLS in the study cohorts, demonstrating its potential for robust performance across a wide range of cardiac functions, different image qualities, and machine types.

Zi-Sang Zhang, Ye Zhu, Shu-Jun Chen et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.