Skip to content
Conference Open access

Simulation of Pulsatile Non-Newtonian Carreau Blood Flow in an Axisymmetric Porous Artery with Multiple Stenoses under MHD Effects

Sep 2026 · 2026 IEEE International Conference on Advances in Computing Research On Science Engineering and Technology (ACROSET) · pp. 1-8 · 0 citations · 21 references

TL;DR

The study provides new insights into the coupled impact of Carreau rheology, porous arterial walls, and magnetohydrodynamic modulation in multi-stenosed arteries, which may contribute to improved understanding of hemodynamic regulation and potential biomedical applications such as magnetic-assisted therapy and thrombosis prevention.

Abstract

A numerical investigation is conducted to examine pulsatile Carreau blood flow in a porous artery containing multiple stenoses under magnetic field effects. The rheological behavior of blood exhibits non-Newtonian characteristics, where apparent viscosity reduces as the deformation rate increases. A user-defined function (UDF) was employed in ANSYS Fluent 2025 R1 to account for the damping effect produced by the applied transverse magnetic field. A systematic numerical investigation was conducted to assess the effects of stenosis severity ($\delta = 10{{\% }},30{{\% }},40{{\% }}$) and magnetic interaction parameter (M=5,20,40) on key hemodynamic quantities, including axial velocity, wall shear stress (WSS), and pressure coefficient (Cp). The reliability of the numerical framework was established through mesh-independence testing (GCI = 0.79%) and validation against available analytical and CFD-PIV results, showing discrepancies below 4%. It was observed that increasing stenosis severity from 10% to 40% markedly amplifies flow acceleration, producing increases of nearly 48% in peak axial velocity, 62% in wall shear stress, and 41% in pressure coefficient (Cp) at the stenotic throat. Conversely, increasing the magnetic interaction parameter from M = 5 to 40 suppresses axial velocity by about 15-28% due to Lorentz force damping, while moderately increasing WSS and Cp by 10-22%. The combined effects of stenosis geometry and magnetic field influence are clearly reflected in the velocity contours, wall shear stress distributions, and pressure coefficient profiles. The study provides new insights into the coupled impact of Carreau rheology, porous arterial walls, and magnetohydrodynamic modulation in multi-stenosed arteries, which may contribute to improved understanding of hemodynamic regulation and potential biomedical applications such as magnetic-assisted therapy and thrombosis prevention.

Read PDF

Similar papers

Open access Oct 2026

Pulsatile non-Newtonian blood flow in arterial aneurysms: Parametric hemodynamic characterization using the finite volume incompressible lattice Boltzmann method

Arterial aneurysms pose a significant public health challenge, with their rupture leading to life-threatening cardiovascular complications. The present study investigates the interplay between aneurysm size, pulsatile flow conditions (Reynolds and Womersley numbers), blood rheology (Carreau number), and key hemodynamic...

Akshay Dongre, Song-Lin Yang · 0 citations
Sep 2026

Non-Newtonian Hemodynamics of Hybrid Nanofluids in a Stenotic Bifurcated Artery: A Magnetohydrodynamic Lattice Boltzmann Study

This study investigates the magnetohydrodynamic (MHD) behaviour of a hybrid nanofluid composed of gold (Au) and silver (Ag) nanoparticles flowing through a stenosed bifurcated artery. A fully coupled mesoscopic numerical model is implemented, in which both the velocity field and the magnetic induction equation are solv...

Fatima Zahra Neflas, S. Bettaibi · 0 citations
Oct 2026

Numerical simulation of electroosmotic blood flow through progressive stenotic artery with a catheter under the joule heating and magnetic field effects.

Atherosclerosis, a condition causing the narrowing of the arteries, is a major contributor to the development of cardiovascular diseases. This emphasizes the importance of examining the rheological behavior of blood flow through such arteries. The mathematical model serves as a framework to gain an understanding of the...

Anushka Keshari, Supriya Yadav · 0 citations
Open access Oct 2026

Mathematical Modelling of the Effects of Trans Fat on Bioheat Transfer and Magnetohydrodynamic Blood Flow through a Constricted Channel Using the Oscillatory Perturbation Method

The model provides a theoretical study for understanding coupled haemodynamic, thermal, and concentration-transport processes associated with atherosclerotic arterial constriction and provides a basis for future patient-specific and experimentally validated investigations.

K. Bunonyo, Peter Benneth · 0 citations
Open access Oct 2026

Finite element analysis of conjugate heat transfer and non-Newtonian blood flow in a stenosed bifurcated artery

In the present study, a detailed numerical analysis is conducted for conjugated heat transfer in non-Newtonian blood flow in a stenosed bifurcated artery. The purpose of the present study is to investigate the coupling mechanisms between the arterial geometry, flow behavior and heat transfer under physiologically meani...

Muhammad Salim Khan, Shafee Ahmad, Zahir Shah et al. · 0 citations
Open access Sep 2026

A Mathematical Model of Pulsatile Blood Flow in Stenotic Vessel Using the Finite Difference Method

Stenosis causes changes in blood flow characteristics that affect velocity distribution, thereby requiring a mathematical model to analyse these changes. This study aims to develop a mathematical model of pulsatile blood flow in a stenosed vessel and to analyse the effects of two degrees of stenosis ( and ) and two Rey...

Zahra Kandini Shabirah, K. Yulianti, Endang Cahya Mulyaning Asih · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.