Skip to content
Open access

Condition-Aware ARIMA Cleaning of Substation Equipment Time Series with Local Residual Scaling and Audit Records

Sep 2026 · Energies · Vol 19, pp. 4522 · 0 citations · 21 references

TL;DR

The evidence supports volatility adaptation and traceable decision output, not universal accuracy superiority or field-proven effectiveness, in the double-loop AO/IO framework added by this study.

Abstract

Distinguishing data quality defects from genuine operating-condition changes is a central challenge in cleaning substation equipment time series. This study extends the double-loop AO/IO framework of Yan et al. by adding local residual scaling, retain-first state screening, constrained correction, model-conditional prediction intervals, and record-level audit fields; the double-loop structure itself is not claimed as new. Evaluation used six deliberately selected field-derived series (two from each of three data sources) with reproducible synthetic labels. The prior correction cap, which allowed corrections to at most 5% of samples, was disabled. Across 18 representative paired runs and 516 injected points, the proposed method obtained F1 = 0.9647 ± 0.0337, whereas fixed-threshold AO/IO obtained 0.9728 ± 0.0308; the six-series paired comparison did not establish a difference (t-test p = 0.0707; Wilcoxon p = 0.1250). In a constructed heteroscedastic stress test, mean F1 increased from 0.4675 to 0.4941 and low-volatility recall from 0.1458 to 0.2667, but this scenario was designed around variance changes and contains only six independent source series. A second spike-only test retained the naturally varying volatility of measured segments and produced F1 = 0.4835 versus 0.4345, but the series-clustered difference was not significant (p = 0.4489). The evidence therefore supports volatility adaptation and traceable decision output, not universal accuracy superiority or field-proven effectiveness. Prediction intervals are approximate and conditional on the fitted model.

Read PDF

Similar papers

Open access Sep 2026

Leakage-Controlled Grouped Validation and Interval-Safety Calibration for RUL/SOH Prediction Using Engine, Battery, and Bearing Degradation Data

In predictive maintenance, low average error is not enough. Serious mistakes can occur near intervention thresholds when a model understates degradation despite acceptable root mean squared error (RMSE) or mean absolute error (MAE). This paper presents a leakage-controlled grouped validation framework for remaining use...

Adel BenAbdennour · 0 citations
Open access Sep 2026

Machine Learning-Based Discrimination of Pre- and Post-Cleaning Marine Turbocharger Recordings Using Rotational-Speed Signals

Monitoring marine turbocharger condition under real-ship operation is complicated by operating-condition variability and limited labelled maintenance data. This study assesses whether mean-centred angle-domain rotational-speed fluctuations can discriminate between six recordings acquired before and after one turbocharg...

Xiang-Rui Ma, Chaitanya Patil, Xing-Ming Zhang et al. · 0 citations
Open access Sep 2026

LEADI: Operating-Mode-Aware Machine Condition Monitoring for Leak-Related Energy Anomalies—A Before-and-After Maintenance Study of a Single Production Asset

Compressed-air leaks create persistent parasitic demand, but machine-level condition monitoring is difficult because air consumption changes strongly with operating mode. LEADI (Leak Energy Anomaly Detection Index) was developed as an operating-mode-aware procedure that evaluates the deviation of directly measured flow...

T. Titova, R. Kosturkov · 0 citations
Review Open access Sep 2026

Audit-Aware SSDI-MoE Framework for Periodic Health Assessment of Centrifugal Chillers in Existing Buildings

The large stock of existing buildings creates demand for chiller assessment during energy retrofit and operation. However, many methods assume access to water flow, separately metered chiller power, and real-time cooling capacity. These measurements are often unavailable in existing plants, preventing online COP calcul...

Hong-Yu Guo, Jia Wang · 0 citations
Conference Open access Sep 2026

Reduction of Electrical Equipment Monitoring Time Series While Preserving Extreme and Rapidly Changing Segments

Continuous monitoring of electrical equipment generates long time series that inflate storage needs and slow down visualisation, diagnostics, and data analysis. Standard uniform downsampling or interval averaging reduces data volume but often suppresses short-duration extremes and abrupt changes - events that are criti...

D. A. Torbostaev, V. Kukartsev, D. S. Tuleninov · 0 citations
Open access 2026

Multivariate Data-Based Anomaly Characterisation of a Potential Pallet-Associated Event in a Manufacturing Conveyor System

Manufacturing conveyor disturbances may not be adequately characterised by single-sensor thresholds because operating changes can appear across multiple sensor channels. This study examined whether a recorded M4 pallet-static event contained multivariate sensor patterns that differed from a recorded M4 stall condition....

L. Odejimi, Olusesan Orebanjo, Olorunleke Aragbe et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.