Dynamic control of carbon‐ion radiation dose distribution amid respiratory motion challenges: A review of prediction research using geant4 and deep learning physics‐constrained models
Oct 2026· Journal of Applied Clinical Medical Physics· Vol 27· 0 citations· 76 references
Medicine
TL;DR
Combining Geant4‐based Monte Carlo simulations with deep learning frameworks shows emerging promise for controlling carbon ion dose distributions amid respiratory motion, though direct clinical validation for this combination remains limited.
Abstract
Abstract Background Carbon ion radiotherapy (CIRT) offers superior dose conformity and biological effectiveness; however, its precision is highly sensitive to respiratory motion, leading to dose uncertainty and interplay effects that compromise treatment accuracy. Methods A comprehensive literature synthesis was conducted on studies employing motion‐resolved imaging techniques (e.g. SMEIR), dynamic dose prediction, 4D robust planning, and hybrid adaptive methods for CIRT. The study emphasised the use of Geant4 Monte Carlo simulations combined with deep learning models, including physics‐informed neural networks, to simulate and predict dose perturbations caused by respiratory motion. This review also examined clinical treatment planning systems, radiobiological modelling, and adaptive strategies to mitigate the effects of motion. Results The integration of Geant4 with deep learning enabled high‐fidelity, computationally efficient dose prediction under respiratory motion, improving accuracy in dose localization and adaptation. Motion management techniques such as respiratory gating, rescanning, and 4D robust optimization demonstrated enhanced tumor control and normal tissue sparing. Hybrid models combining Monte Carlo data and AI inference show promise for near‐real‐time adaptive therapy. Despite these advances, challenges remain, including limited motion‐rich datasets, computational demands for real‐time recalculations, and the complexity of incorporating variable relative biological effectiveness (RBE) into adaptive planning. Conclusions Combining Geant4‐based Monte Carlo simulations with deep learning frameworks shows emerging promise for controlling carbon ion dose distributions amid respiratory motion, though direct clinical validation for this combination remains limited. These hybrid models may enhance the precision and adaptability of CIRT, offering improved outcomes. Future efforts should focus on clinical validation, standardization, and overcoming computational and data limitations to facilitate clinical translation of motion‐adaptive CIRT. These approaches remain at Technology Readiness Levels (TRL 3–5) and require prospective clinical validation before routine implementation.
Purpose: Respiratory motion is a major challenge in proton therapy (PT) for thoracic tumors, causing interplay effects that degrade dose distribution. While Monte Carlo (MC) simulation is the gold standard for dose calculation, its computational burden hinders real-time adaptive use. This study aims to develop and vali...
Hadi TaleshiAhangari, Ahmad Saud Dakhel Alkatan· Advances in Medical Pyhsics...· 0 citations
Purpose: Deep learning can accelerate radiotherapy dose prediction, but particle-therapy datasets remain scarce. We evaluated whether a physics-informed ensemble trained exclusively on photon plans could predict proton and carbon-ion dose distributions without particle-dose training.Methods: Using matRad, 90 reference...
Muhammed Emin Bedi̇r· Acibadem Universitesi Saglik...· 0 citations
The proposed framework provides a foundation for next-generation automated treatment planning systems and motivates future extension to patient-specific, clinically realistic scenarios.
L. Arsini, B. Caccia, A. Ciardiello et al.· International Journal of Par...· 0 citations
This work replaces the standard MSE training objective with a differentiable $\gamma$-index-based loss, extended to native 3D operation, and demonstrates that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate that is critical for clinical deployment.
J. Jawaid, M. Spezialetti, Gabriele Libardi et al.· 0 citations
The integration of geometric surface features with patient‐specific physical constraints successfully prevents nonphysiological deformation artifacts caused by sensor noise and demonstrates the feasibility and computational efficiency of the PIDE framework for rapid cumulative dose monitoring.
The proposed atlas-normalized model achieved robust discrimination, and a 9-case plan-refinement analysis showed that CAM- and GM-derived spatial information could be translated into clinically constrained avoidance objectives that reduced the model-predicted RIX probability while preserving specified target and organs...
Bo-Hua Wan, T. McNutt, Harry Quon et al.· Physics in Medicine and Biol...· 0 citations