Oct 2026· European Heart Journal· Vol 47· 0 citations
TL;DR
The use of physiology-integrated FFR-CT to refine non-invasive selection of patients for invasive coronary angiography and revascularization and improves diagnostic accuracy and agreement versus benchmark anatomy-only FFR-CT, including within the grey zone of intermediate lesions.
Abstract
Fractional flow reserve derived from coronary computed tomography angiography (FFR-CT) is recommended for non-invasive evaluation of intermediate coronary artery stenoses. However, a recent meta-analysis showed that contemporary anatomy-only FFR-CT methods provide moderate agreement with invasive FFR with reduced discrimination in the intermediate “gray-zone” where clinical decisions are often most challenging. We hypothesized that integrating individual pressure-waveform hemodynamics into FFR-CT computation could improve functional assessment of coronary lesions, particularly in this diagnostically challenging range.
We developed a waveform-enhanced FFR-CT algorithm that incorporates Continuous Non-invasively measured Blood Pressure (CNBP) waveforms as patient-specific physiological to determine boundary conditions for Computational Fluid Dynamics models of coronary flow. FFR-CT values were computed along the coronary tree and adjusted to the invasive FFR measurements, with FFR ≤0.80 considered hemodynamically significant. In this multicenter study, 167 vessels from 132 patients enrolled in the NCT04777513 trial were analyzed. Diagnostic performance of waveform-enhanced FFR-CT was compared against invasive FFR and benchmarked against collected off–site FFR-CT results from a recent temporary meta-analysis including 2423 vessels, restricted to prospective diagnostic accuracy studies reporting vessel-level FFR-CT versus invasive FFR.
Per-vessel analysis showed excellent diagnostic performance of waveform-enhanced FFR-CT, with an AUC of 0.916 (95% CI 0.868–0.956) and overall diagnostic accuracy of 88.6% for detecting functionally significant stenoses versus invasive FFR. Sensitivity and specificity were 92.5% and 87.4%, respectively, compared with 81.5% and 77.7% for benchmark FFR-CT (p=0.027 and p=0.0021), and AUC was significantly higher (0.916 vs 0.858; p=0.026). Bland–Altman analysis demonstrated minimal bias between invasive FFR and waveform-enhanced FFR-CT (mean difference −0.01, 95% limits of agreement −0.21 to 0.19) and a Pearson correlation coefficient of 0.69 with a regression slope close to unity. In the clinically relevant grey-zone subgroup (FFR 0.75–0.85), diagnostic accuracy remained high with waveform-enhanced FFR-CT (81.2% vs 65.4% for benchmark FFR-CT; p=0.003), with higher specificity (79.6% vs 59.7%; p=0.0014) and numerically higher sensitivity (85.0% vs 72.7%; p=0.14).
An individual physiology-enhanced FFR-CT approach that integrates patient-specific pressure–waveform dynamics into coronary CFD modeling improves diagnostic accuracy and agreement versus benchmark anatomy-only FFR-CT, including within the grey zone of intermediate lesions. These findings support the use of physiology-integrated FFR-CT to refine non-invasive selection of patients for invasive coronary angiography and revascularization.Accuracy of Cardiolens FFR-CT Pro
Coronary perivascular FAI is an independent imaging marker for CT-FFR-defined functional ischemia and provides incremental value beyond traditional risk factors and EAT volume, support FAI as a non-invasive marker of coronary inflammation that may refine risk stratification for functionally significant coronary artery...
Zhi-Hong Gao, Lin-Hui Jia, Min Jia· Frontiers in Cardiovascular...· 0 citations
OBJECTIVE
While pressure-wire based fractional flow reserve (FFR) is considered the gold standard for evaluating coronary lesion significance, its use in daily clinical practice remains limited.Angiography derived vessel based FFR (vFFR) offers a promising alternative, without the need for pressure wires or hyperaemia...
H. Kovvuri, J. N. Arul, Harsimran S. Singh et al.· Indian Heart Journal· 0 citations
BACKGROUND: The diagnostic value of coronary computed tomography angiography–derived fractional flow reserve (FFR-CT) in stable coronary artery disease is well established. The prognostic value of predicting future cardiovascular events is less clear, as studies are limited by small populations, variable measurement po...
Jack S. Bell, Edward D. Nicol, Vinod Venugopal et al.· Circulation· 0 citations
Objectives: To determine whether quantitative coronary computed tomography angiography (CCTA) plaque characteristics associated with fractional flow reserve (FFR)-defined ischemia vary among coronary arteries and whether they improve prediction when added to conventional clinical and stenosis information. Methods: This...
Shuang Li, Tian Ma, An-Qi Yang et al.· Diagnostics· 0 citations
Coronary artery disease (CAD) is a major global cause of morbidity and mortality. While coronary computed tomography angiography (CCTA) offers excellent anatomical assessment, its ability to determine the functional relevance of intermediate stenoses remains limited. Computed tomography–derived fractional flow re...
J. Vornanen, M. Okkonen, A. Ronkainen et al.· European Heart Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.