Skip to content
Open access

Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter Uncertainties

Oct 2026 · Wind · 0 citations

Abstract

Wind energy conversion systems based on dual-star induction generators (DSIGs) exhibit nonlinear dynamics and sensitivity to operating-condition variations, which can adversely affect power tracking, DC-link voltage regulation, and power quality. This study proposes a fractional-order backstepping control strategy optimized by the Ant Lion Optimizer (FOBC-ALO) for a DSIG-based wind energy conversion system. The fractional-order formulation provides an additional degree of freedom for shaping the controller response, while the ALO algorithm is employed to optimize the controller gains. The fractional order is selected through a sensitivity analysis, with α = 0.5 providing the most balanced performance among tracking accuracy, transient response, DC-link voltage regulation, and harmonic distortion. The proposed controller was implemented and evaluated in MATLAB 2021/Simulink and compared with a conventional backstepping controller under four simulation scenarios involving variable wind-speed profiles, machine-parameter variations, stepwise wind-speed changes, and operation without maximum power point tracking. The results show that the proposed controller consistently improves the dynamic and power-quality performance of the DSIG-based system. In the first test, the active-power response time was reduced from 1.66 to 1.32 ms, while the current total harmonic distortion (THD) decreased from 1.87% to 1.06%. Under 100% variations in the selected machine parameters, the THD decreased from 5.13% to 2.13%, while the DC-link voltage fluctuation was reduced from 10.18 to 3.02 V. For the stepwise wind-speed test, the proposed controller reduced the active-power response time by 47.99%, the ITAE by 63.70%, the DC-link voltage fluctuation by 71.90%, and the current THD by 48.69%. In the operation without MPPT, the integral of time multiplied by squared error (ITSE), integral of time multiplied by absolute error (ITAE), DC-link voltage ripple, and current THD were reduced by 41.28%, 57.67%, 74.88%, and 46.94%, respectively. Overall, the simulation results indicate that the proposed FOBC-ALO strategy improves reference tracking, transient response, DC-link voltage regulation, and current waveform quality across the investigated operating conditions. The findings provide a simulation-based foundation for subsequent real-time and experimental validation of fractional-order control for DSIG-based wind energy conversion systems.

Read PDF

Similar papers

Open access Oct 2026

Nonlinear Derivative Synergetic Speed Control for TSR-Based Maximum Power Extraction in PMSG Wind Energy Conversion Systems

Efficient maximum power extraction under rapidly varying wind conditions remains a major challenge for variable-speed wind energy conversion systems (WECSs). This paper proposes a nonlinear derivative synergetic mode controller (DSMC) for robust rotor speed regulation in a permanent magnet synchronous generator (PMSG)-...

Abdelkrim Adila, Khedidja Kendouci, N. Bouchetata et al. · 0 citations
Oct 2026

Enhanced MPPT Control For DFIG-Based Wind Energy Systems Using Tunable Fractional-Order PI Controllers

The global urgency to reduce reliance on depleting fossil fuels and mitigate climate change has intensified the pursuit of clean, renewable energy alternatives. Among these, wind energy emerges as a promising solution due to its scalability and suitability for integration into large power grids. Nevertheless, the varia...

Y. K. Teklehaimanot · 0 citations
Open access Oct 2026

Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution

This paper proposes a supervisory control framework for a 6-MW wind farm (WF) comprising four 1.5-MW doubly fed induction generator (DFIG)-based wind turbines (WTs) to improve power quality and mitigate electrical and mechanical stresses under grid-pollution conditions. A backstepping control (BC) strategy is implement...

Abdelkader Achar, Y. Djeriri, H. Benbouhenni et al. · 0 citations
Open access Oct 2026

Genetic Algorithm-Optimized Active Disturbance Rejection Control for Robust Voltage Regulation in Standalone DFIG-Based Wind Energy Systems with Battery Storage: Real-Time Experimental Implementation

The design, modeling, and experimental validation of a Genetic Algorithm (GA)-optimized Active Disturbance Rejection Control (ADRC) strategy for voltage regulation in a standalone Wind Energy Conversion System (WECS) based on a Doubly Fed Induction Generator (DFIG) are presented in this study. The proposed system is de...

Najoua Mrabet, Mohssine Chakib, Chirine Benzazah et al. · 0 citations
Open access Sep 2026

Experimental Implementation of a Second-Order Adaptive Fuzzy Logic Controller for PMSG-Based Wind Energy Conversion Systems

This study presents a second-order adaptive fuzzy logic controller (SO-AFLC) to enhance the dynamic performance of permanent magnet synchronous generator (PMSG)-based wind energy conversion systems (WECSs). The proposed controller simultaneously performs maximum power point tracking (MPPT), DC-link voltage regulation,...

B. Elnaghi, H. Abdelhafez, Mohamed M. Isamail et al. · 0 citations
Conference Open access Sep 2026

Enhanced Active Power Control and Low-Voltage Ride-Through for Offshore PMSG Wind Turbines Using Model Predictive Control

This paper presents a comprehensive analysis and design of an enhanced control framework for offshore wind turbine generators (WTGs) equipped with permanent-magnet synchronous generators (PMSGs) and full-scale power converters. The proposed strategy integrates Model Predictive Control (MPC) for maximum power point trac...

K. A. Baizhanov, S. Issenov · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.