Qualitative and Quantitative Comparison of Readout-Segmented and Single-Shot Echo-Planar Diffusion-Weighted MR Imaging of the Prostate At 3.0 T

Oct 2026 · Journal of Gastrointestinal and Abdominal Radiology · 0 citations · 27 references

Abstract

Abstract Aims and objectives The aim of the study is to qualitatively and quantitatively compare the diagnostic value of diffusion-weighted (DW) magnetic resonance (MR) imaging based on standard single-shot echo-planar imaging (ss-EPI) and readout-segmented echo-planar imaging in patients with prostate cancer at 3.0 Tesla. Materials and methods All patients referred with suspected prostate cancer, underwent multiparametric MR imaging (mpMRI) using our 3.0-T MR imager (Magnetom Skyra, Siemens Healthineers, Erlangen, Germany). In all patients, DW imaging was carried out first using ss-EPI and later using readout segmentation of long variable echo-trains (RESOLVE) sequence. RESOLVE is a type of multishot readout-segmented echo echo-planar imaging (rs-EPI) technique with an additional two-dimensional navigator for robust correction of motion-induced phase errors. Two independent readers visually assessed image quality, lesion conspicuity, and geometric distortions using a 5-point Likert scale. Image properties, such as signal-to-noise ratio, contrast-to-noise ratio, apparent diffusion coefficient (ADC) values, were also quantified. Results Both readers demonstrated good-to-excellent interreader agreement for the qualitative image-quality parameters. RESOLVE demonstrated significantly higher scores for overall image quality, lesion conspicuity, and reduced geometric distortion compared with ss-EPI (all p  < 0.05). Quantitatively, the mean SNR was significantly higher with RESOLVE than with ss-EPI (11.8 ± 4.3 vs. 9.2 ± 4.7, p  = 0.021). The mean contrast-to-noise ratio was also higher with RESOLVE (3.7 ± 4.2 vs. 3.0 ± 3.0), although the difference did not reach statistical significance ( p  = 0.055). Mean ADC was lower with RESOLVE than with ss-EPI (0.717 ± [SD] × 10  − 3 vs. 0.821 ± [SD] × 10  − 3  mm 2 /s), with no statistically significant difference ( p  = 0.058). Conclusion Compared with conventional ss-EPI, the use of rs-EPI for the acquisition of prostate diffusion-weighted imaging (DWI) resulted in significantly enhanced anatomical delineation, lesion conspicuity, and reduced geometric distortion. Therefore, rs-EPI could be an alternative to or replacement for ss-EPI for acquiring prostate DWI at 3.0 Tesla.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.