Oct 2026· JBJS Reviews· Vol 14· 0 citations· 23 references
Medicine
TL;DR
Metal hypersensitivity reactions following spinal implants are infrequently reported but may present either immediately or in a delayed manner with symptoms that mimic more common postoperative complications, such as infection or pseudarthrosis, or may present with dermatologic manifestations.
Abstract
Background: Metal hypersensitivity reactions are infrequently reported but clinically significant after spinal implant surgery. Clinical presentation can mimic infection or mechanical failure, making diagnosis difficult. Evidence to guide diagnosis and management is largely limited to short case series and case reports. The purpose of this study was to systematically review the clinical presentation, diagnostic methods, and outcomes of metal hypersensitivity associated with spinal implants. Methods: A systematic review was conducted of PubMed, Embase, and Scopus from inception through June 22, 2026, in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Title and abstract screening, full-text review, and data extraction were performed independently by 2 reviewers with conflicts resolved by a third reviewer. Eligible studies included adult patients with suspected or confirmed metal hypersensitivity following spinal implant surgery that reported patient-level clinical outcomes. Results: Fifteen studies with a total of 19 patients met inclusion criteria (53% female, 42% male, and 5% not reported). The median patient age was 47 years (range, 19-69). Twelve procedures (63%) were fusion-based, while 7 (37%) were motion preserving, including disk arthroplasty and artificial facet replacement systems. Common clinical presentations included persistent pain, with 8 patients (42%) exhibiting dermatologic manifestations. Metal hypersensitivity was immunologically confirmed by positive patch testing and/or lymphocyte transformation testing in 11 patients (58%), while 8 (42%) were diagnosed clinically. Onset of symptoms ranged from immediately postoperatively to 15 years after implantation. Eighteen patients underwent removal or revision with clinical improvement in 14 of 16 with a reported outcome (88%). Conclusion: Metal hypersensitivity reactions following spinal implants are infrequently reported but may present either immediately or in a delayed manner with symptoms that mimic more common postoperative complications, such as infection or pseudarthrosis, or may present with dermatologic manifestations. In cases where other etiologies are ruled out, hardware removal was frequently, though not invariably, associated with clinical improvement, which was reported narratively rather than by validated outcome measures. Level of Evidence: Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.
Metal hypersensitivity is an increasingly recognized factor in orthopedic implant failure, particularly in patients undergoing total joint arthroplasty (TJA), and may contribute to persistent pain, aseptic loosening, or early revision. This review synthesizes current evidence on the underlying immune mechanisms of meta...
Veronica Viola, N. Marelli, Teofila Caplanusi et al.· EFORT Open Reviews· 0 citations
Background: Chronic postsurgical pain is well recognized after major surgical procedures but often overlooked following thyroidectomy. Given the increasing frequency of this surgery, this systematic review and meta-analysis aimed to synthesize current evidence on the incidence, characteristics, and modulating factors o...
C. Chaves, M. Frias, Luís Guimarães-Pereira· Medicine· 0 citations
Background. Maxillofacial trauma represents a significant public health concern, with road traffic accidents (RTAs) among the leading causes in adults, although other mechanisms are also common. Despite advances in surgical techniques, postoperative complications may include infection, impaired wound healing, malocclus...
M. Koyuncu, Mohammad Alizadeh· Romanian Journal of Stomatol...· 0 citations
. Peri‑implantitis is a biofilm‑induced, immune‑medi-ated inflammatory condition affecting ~1 in 5 patients bearing implants and remains one of the most clinically unresolved challenges in contemporary implantology. Although multiple therapeutic approaches have been proposed, no universally accepted treatment protocol...
Richik Chakraborty, Nina Shenoy, A. Talwar et al.· World Academy of Sciences Jo...· 0 citations
BACKGROUND
Fracture-related infection (FRI) remains a challenge in orthopedic trauma care. Conventional culturing of deep intraoperative samples is the current diagnostic standard, but confirmation occurs postoperatively, delaying targeted treatment. Real-time intraoperative diagnostic techniques may offer earlier, mor...
L. Bessems, Arthur Meuris, J. Onsea et al.· Injury· 0 citations
Background Spinal infections are difficult to cure, especially when implants are present, because implant removal can destabilize the spine. Continuous local antibiotic perfusion (CLAP) delivers high-concentration antibiotic directly to the infected site. We systematically reviewed and descriptively synthesized the rep...
Fumihiro Inoue, Hirohito Hirata, N. Yamamoto et al.· Journal of Spine Surgery· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.