2026· IEEE Transactions on Instrumentation and Measurement· Vol 75, pp. 9008816-9008816· 0 citations· 30 references
Abstract
Flat cables, one of the main power supply cables for mobile electrical equipment, are prone to arc faults due to insulation damage caused by external forces during operation. Due to the special structures and parameters of flat cables, there may exist significant errors in fault location when using traditional methods when facing with measurement challenges. This article first establishes the equivalent circuit model for flat cables with arc faults by considering the multiconductor structure and coupling electrical parameters. The time-domain expressions of currents flowing in conductors, together with the relation between voltages and currents at the fault point, are derived. The equations regarding fault distance and resistance are formulated to achieve accurate fault location. Signal filtering, a nonlinear least-squares framework, and synchronous measurement error estimation are employed to form the method to reduce the effects of noise interference and measurement errors in method implementation. Finally, the experimental model of a flat cable system was built using a real-time digital simulator (RTDS). The method was validated under various fault scenarios and measurement errors. Experimental results show that the fault location error does not exceed 2.25 m under various scenarios.
Single-line-to-ground (SLG) faults in medium-voltage distribution networks can produce significant capacitive currents and transient overvoltages, particularly in cable-dominated networks with different neutral-grounding arrangements. This study develops a phase-coordinate modeling framework for three-phase distributio...
S. Lebedka, I. Diahovchenko, M. Petrovskyi et al.· Electronics· 0 citations
The continuous increase in the demand for electrical energy and the associated expansion of power networks are driving the need for ever-improving operational reliability, safety, and the diagnostic value of measurement techniques. In polymer-insulated cable systems, partial discharge (PD) measurement has already becom...
Roberto Piccin, K. Vaterrodt, Krzysztof Kucharczyk et al.· 2026 International Conferenc...· 0 citations
This article examines the pressing issue of ensuring fire safety in low-voltage cable lines (up to 1000 V) related to electric arcs. It is shown that traditional protection measures-circuit breakers and residual-current devices (RCDs)-are not always effective, especially during sequential arc faults, when the arc curre...
A. Tyurin, Y. Soluyanov, A. Akhmetshin· 2026 International Russian A...· 0 citations
To address the difficulty of online and accurate identification of insulation damage faults in multiple parallel cables within urban rail transit DC traction power supply systems, this paper proposes a fault identification method based on the Current Deviation Degree (CDD). This method analyzes the deviation characteri...
Zhou-Qin Zhou, Xue-Tao Liu, Gang Zhang· Journal of Physics, Conferen...· 0 citations
Wide-bandgap (WBG) inverter drives impose repetitive high-frequency voltage stress, accelerating insulation degradation and increasing the probability of short-circuit faults in cables and machine windings. However, existing online diagnostic approaches face significant deployment barriers due to their sensitivity to e...
Yue Yu, Hu-Jun Peng, S. Steentjes· 2026 International Conferenc...· 0 citations
Bulk current injection (BCI) is a standardized immunity test method for automotive subsystems connected via electrical cables and harnesses. While BCI tests are performed using fixed configurations, real vehicle installations exhibit significant variations in cable length and grounding conditions. Since BCI-induced dis...
Manuel Mikschl, Reinhard Stolle· International Conference on...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.