The Phase Angle of Injected Circulating Current and Common-Mode Voltage Components and Its Impact on Submodule Capacitor Voltage in the Modular Multilevel Converter
Sep 2026· 2026 IEEE 22nd International Power Electronics and Motion Control Conference (PEMC)· pp. 1-6· 0 citations· 16 references
Abstract
In this study, a high-frequency common-mode injection approach aimed at reducing capacitor-voltage ripple in a modular multilevel converter (MMC) is considered, and the injection-voltage expression commonly used in the literature is extended to include a phase term. Accordingly, a phase-adjusted injection model is defined by introducing the phase angle $\theta_{z}$ into the injection voltage $u_{z}$, and the time-domain effects of this parameter on the capacitor-voltage ripple and the high-frequency circulating-current component are investigated. The simulation results indicate that $\theta_{z}$ is not limited to introducing a horizontal phase shift in the waveform; rather, it provides a performancecritical degree of freedom that significantly influences the ripple amplitude and the associated circulating-current magnitude. Moreover, the $\theta_{z}$ sensitivity analysis shows that the ripple does not follow a consistent trend with respect to the phase angle and can increase sharply within a specific phase region. Finally, the relationship between the peak-to-peak capacitor-voltage ripple and the root-mean-square value of the circulating current suggests that the choice of $\theta_{z}$ governs the balance between ripple reduction and circulating-current stress. Additional simulations conducted under different modulation indices, fundamental frequencies, and load conditions also demonstrate that the influence of $\theta_{z}$ is not limited to the baseline operating point.
This paper develops a capacitor-voltage ripple-control scheme that combines negative-sequence second-harmonic capacitor-voltage feedback with third-harmonic zero-sequence voltage injection. An arm-energy model incorporates the common dc current, auxiliary-MMC voltage allocation, and ac support duty. The dc-series conne...
Long Zhao, Li-Na Zhang, Zhen-Hua Yuan et al.· Electronics· 0 citations
To address the challenge of zero-current interruption of a bypass switch (BPS) during valve group energization in modular multilevel converter (MMC)-based ultra-high-voltage direct current (UHVDC) systems, this paper proposes a novel single-phase asymmetric harmonic injection control strategy. The injection of harmonic...
Jie-Feng Wang, Jun-Hui Ren, Hao Wang et al.· IEEE Access· 0 citations
In this paper, an equivalent frequency-domain common-mode (CM) model is presented for a five-level active-neutral-point-clamped (ANPC) inverter and validated against the full time domain model. The equivalent model highlights additional High Frequency (HF) sources that are not apparent in the time-domain CM voltage mea...
Georgios Erotas, Patrick Koch, N. Moonen et al.· International Conference on...· 0 citations
Multilevel topologies have been used more frequently for high voltage applications in order
to produce a staircase voltage waveform with total harmonic distortion (THD). This has
increased interest in high-power systems and prompted the continuous development of
advanced topologies. This paper discusses the advantages...
Miteshkumar N. Priyadarshi, Sandeep Chakravorty· ITEGAM- Journal of Engineeri...· 0 citations
Parallel interleaved voltage-source inverters (VSIs) are widely employed in high-power applications to improve power capability, efficiency, and output current quality. However, interleaving also introduces high-frequency circulating currents between parallel inverter legs, which increase losses and constrain the desig...
M. Naveed, T. Hoeksma, T. Soeiro· 2026 IEEE 22nd International...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.