Sensor noise is a fundamental barrier to low-flux astronomical imaging and spectroscopy, where the ideal sensor would unambiguously distinguish individual photon arrivals. While optical semiconductor arrays can reach single-photon sensitivity, comparable performance in the infrared has largely required superconducting detectors. These must be operated at temperatures near absolute zero and require substantially more power, introducing major system-level challenges. HgCdTe avalanche photodiodes offer a semiconductor alternative by amplifying charge before readout, but dark current and tunneling effects have limited their use in the faintest regimes. Here we demonstrate single-photon-resolving operation in a megapixel-format HgCdTe linear-mode avalanche photodiode array operated at conventional cryogenic temperature. Avalanche gain raises photon-induced steps in non-destructive up-the-ramp data above the readout-noise floor while leaving the dark signal largely unamplified, with a false positive rate of approximately 2 false counts per thousand reads per pixel. These results establish LmAPDs as a promising route toward infrared photon-counting focal planes for future low-background astronomical observatories.
Measuring rapid astrophysical phenomena requires many short exposures, which suffer from repeated read noise. A variety of recent technologies are achieving sub-electron read noise, which enable rapid time-domain studies of faint sources. These data can be analyzed with traditional methods, but the ability to resolve i...
Jack T. Dinsmore, Christopher Layden, R. Romani et al.· 0 citations
Microwave Kinetic Inductance Detectors are superconducting resonators capable of single-photon counting with energy resolving capability at visible and near-infrared wavelengths. Their zero read noise, extremely low dark counts, and compatibility with frequency-division multiplexing make them well suited for large imag...
W. Ras-Vinke, H. Schulte, D. Thoen et al.· 1 citation
The far-infrared (FIR) foreground level in space is extremely low, necessitating highly sensitive detectors for space-based continuum observations. To achieve photon-noise-limited performance, FIR detectors require a noise equivalent power (NEP) lower than 3 ×10 −19 W Hz −1/2 and a per-pixel saturation power ( Psat) ra...
Ling-Mei Zhang, Jia-Min Sun, Lin Zhu et al.· Superconductors Science and...· 0 citations
The transition edge sensor (TES) is known for its superior energy resolution and utilized in diverse physics experiments. TESs with micrometer dimensions have photon-number-resolving capabilities in infrared wavelengths, serving as a key device particularly for non-Gaussian quantum state generation in optical quantum...
Y. Mitsuya, R. Matsumoto, Mamoru Endo et al.· Scientific Reports· 0 citations
Transition-edge sensor (TES) microcalorimeters for future X-ray space observatories require accurate low-energy calibration, a regime where conventional X-ray sources are limited by intrinsic linewidth, count rate, or experimental complexity. In this work, we investigate fiber-coupled optical photons as a compact calib...
Giacomo Gorla, B. Sohl, E. Taralli et al.· Italian National Conference...· 0 citations
High-purity germanium (HPGe) detectors are among the most powerful instruments for gamma ray spectroscopy, combining exceptional energy resolution with large active volumes. Although they operate close to the fundamental resolution limit at high energies, their performance at very low energies has long been limited by...
A. Armatol, C. Augier, L. Bergé et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.