Review Open access Oct 2026

Dosimetric comparison of the anisotropic analytical algorithm and Acuros XB for single-fraction cranial stereotactic radiosurgery with a 6 MV flattening filter-free beam

Stereotactic radiosurgery delivers an ablative single-fraction dose to small intracranial targets, and the reported dose depends on the calculation algorithm. This exploratory case series quantified the change in reported dosimetry when plans clinically finalised with the anisotropic analytical algorithm (AAA) were rec...

K. Utitsarn, Thepphithak Watthanasarn, Wirasinee Chaloemchawalit et al. · 0 citations
Open access Oct 2026

Dosimetric Validation of Ethos Online Adaptive Radiotherapy for Prostate Cancer: An End-to-End Phantom Study

Background/Objectives: Online adaptive radiotherapy (oART) re-optimizes treatment on the anatomy of the day, but automatically generated plans require dosimetric verification and dose–volume assessment. We performed an end-to-end validation of the Varian Ethos workflow for prostate cancer, including cross-adaptation be...

M. Janiszewska, M. Raczkowski · 1 citation
Sep 2026

How robust are secondary dose algorithms for Patient-Specific quality assurance in modulated stereotactic Radiosurgery?

PURPOSE Accurate dose verification is essential in stereotactic radiosurgery (SRS), where small fields and steep dose gradients may amplify uncertainties, especially with complex techniques like multitarget single-isocenter VMAT. This technical note evaluated the robustness of two secondary dose calculation algorithms...

E. Mastella, K. E. Szilagyi, Joseph S. Perrine et al. · 0 citations
Open access Oct 2026

Validation of a 3D-printed anthropomorphic eye phantom for quality assurance in external beam radiotherapy using TLD and radiochromic film.

External beam radiation therapy (EBRT) is widely used for uveal melanoma to preserve the eye and achieve effective tumor control. However, late side effects remain a concern, reinforcing the need for dose reduction to mitigate long-term toxicity. This study aims to validate a 3D-printed ocular tissue-equivalent anthrop...

A. Fidelis, D. Batista, S. Cardoso et al. · 0 citations
Sep 2026

Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical 192Ir and 125I brachytherapy sources

This work establishes a robust, cross-validated computational baseline for brachytherapy dosimetry using general-purpose MC codes under realistic photon emission spectra under realistic, unsimplified photon emission spectra.

Lucas Fabrício de Araújo, Asif Amin, Adriano Sabino et al. · 0 citations