Skip to content

Comparison of Artificial Intelligence-Generated and Technician- Designed Maxillary Central Incisor Crowns: An In Vitro Study.

Oct 2026 · International Journal of Prosthodontics · Vol 0 0, pp. 1-26 · 0 citations
Medicine

TL;DR

AI-based crown design systems demonstrated variable performance across evaluated parameters for anterior crowns, while certain systems showed favorable internal surface difference values, others demonstrated more balanced incisal and proximal contact behavior.

Abstract

Purpose

To compare digital designs of maxillary central incisor crowns generated by four artificial intelligence (AI)-based design systems with those created by an experienced dental technician using conventional computer-aided design (CAD) software, with respect to internal surface difference, marginal deviation, incisal and proximal contact characteristics, and design time.

Materials And Methods

Thirty-two anonymized digital datasets of prepared maxillary central incisors were used. For each prepared tooth, five crowns were generated: one by a master dental technician (MDT) and four using AI-based systems (3shape Automate [AU], Atomica [AT], Dentbird [DT], and Exocad AI Design [EX]). Design time and mesh properties (file size, mesh numbers, and crown volume) were evaluated. Internal surface difference and marginal deviation were assessed using three-dimensional root-mean-square (RMS) deviation analysis. Incisal and proximal contact occurrence and contact characteristics were digitally evaluated. Data were analyzed using repeated-measures ANOVA or the Friedman test, followed by appropriate multiple-comparison procedures (α = 0.05).

Results

Significant differences were identified among groups for design time, file size, mesh numbers, crown volume, internal surface difference, marginal deviation, and proximal contact occurrence (P <0.01). AI-based systems required significantly shorter design times than the technician-designed workflow, with AT showing the lowest values and MDT the highest. The DT and MDT groups exhibited the largest mesh numbers, file sizes and crown volumes. The DT group also demonstrated the smallest internal surface difference (71 ±5 μm), whereas the AT group exhibited the greatest marginal deviation (225.64 ±163.1 μm). Incisal contact occurrence varied among the AI systems and was higher in several groups than in the technician-designed crowns (up to 35.71% vs 7.14%). Significant differences were observed in proximal contact occurrence for both mesial and distal surfaces (P <0.01), and the AT group showed the lowest proximal contact occurrence among all groups (3.57% on both mesial and distal). Despite variability among platforms, all systems produced internal surface difference values within clinically accepted thresholds.

Conclusions

AI-based crown design systems demonstrated variable performance across evaluated parameters for anterior crowns. While certain systems showed favorable internal surface difference values, others demonstrated more balanced incisal and proximal contact behavior. Hybrid workflows combining AI assistance with conventional CAD controls demonstrated comparatively consistent outcomes across parameters. Nevertheless, AI-generated crown designs still require professional evaluation and potential refinement before clinical use.

View source

Similar papers

Open access Sep 2026

Effect of AI-Assisted Crown Design on Marginal And Internal Adaptation

Background:Artificial intelligence (AI) has emerged as a promising technology in digital dentistry, particularly in the automated design of dental crowns. Although AI-assisted systems have demonstrated potential in reproducing dental morphology and improving the efficiency of digital workflows, their effect on the marg...

S. Kumari, N. Pavani, A. Roshan et al. · 0 citations
Review Open access Oct 2026

Fully Automated Artificial Intelligence-Based Design Single Tooth-Supported Dental Crowns: A Systematic Review of Efficiency, Fit, and Morphological Accuracy

Abstract Fully automated artificial intelligence (AI)-based dental crown design has recently emerged as an alternative to conventional workflows, including technician-assisted digital design and traditional wax-up techniques. However, the available evidence remains heterogeneous, and no clear consensus exists regarding...

Eloïse Vigroux, J. Mendes, Joana Mendes et al. · 0 citations
Open access Sep 2026

Evaluation of the Accuracy of Dental Implant Placement on Different Cast Models

Introduction: To compare the accuracy of implant placement on mandibular models fabricated from different materials using a single digitally designed surgical guide, and to identify which model provided the highest precision and cost-effectiveness for research and training applications. Materials and Methods: Nine ide...

Raniah Isam Muwafaq al Khashali, Dr. Bayad Jaza Mahmood · 0 citations
Sep 2026

Comparative accuracy of three orthodontic software platforms for mesiodistal tooth-width measurements and bolton analyses in patients with mild to moderate crowding: A retrospective study.

OBJECTIVE The primary aim of this study was to compare mesiodistal tooth-width measurements and Bolton analysis outputs generated by three orthodontic software platforms (3Shape OrthoAnalyzer®, uDesign®, and Titan Dental Design™) against a physical caliper control. The study utilized pre- and post-treatment digital mod...

Hallie Moehring, Qing-Zhao Yu, Zi-Xin Li et al. · 0 citations
Open access Oct 2026

Accuracy and clinical performance of conventional versus digital impressions for maxillary complete dentures: a randomized controlled clinical trial

This study aimed to compare the three-dimensional trueness of digital impressions with conventional impressions for maxillary complete dentures and to evaluate the clinical performance of denture bases fabricated from each technique. Twenty completely edentulous participants received both conventional impressions and d...

M. Habash, Ammar Almustafa, Hasan Alzoubi · 0 citations
Oct 2026

Comparison of digital, semi-digital, and conventional fit evaluation methods for additively and subtractively manufactured zirconia three-unit fixed dental prostheses.

OBJECTIVES To assess the fit of additively and subtractively manufactured zirconia fixed dental prostheses (FDPs) using different evaluation methods and compare alternative methods with the conventional method. METHODS Three-unit FDPs were fabricated additively from zirconia slurry (AM) or subtractively from highly t...

Begüm Ünlü Kurşun, Eleni Trikoili, Mustafa Borga Donmez et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.