Skip to content
Review Open access

An interactive virtual dosimetrist for adjusting radiotherapy dose quality

Sep 2026 · Physics and Imaging in Radiation Oncology · Vol 41, pp. 101080 · 0 citations · 30 references
Medicine

TL;DR

This work is the first to combine deep learning-based dose prediction with natural language processing specifically designed to support the language-conditioned generation of suboptimal dose distributions and their improvement.

Abstract

Background and Purpose: Effective education in radiotherapy plan quality review requires exposure to treatment plans of varying quality and opportunities for plan improvements. However, the current clinic-based paradigm does not fully support these needs. Trainees often review limited numbers of diverse treatment plans and are not fully exposed to the planning decisions essential for developing strong evaluation skills. Materials and Methods: To address these challenges, we developed “Virtual Dosimetrist” models that generate and modify radiotherapy dose distributions through language conditioning, similar to communicating with a planner during plan review. This enables creation of diverse suboptimal examples and real-time, language-guided refinement. Results: The models modify dose distributions following language directives, allowing the generation of lower-quality examples and subsequent improvement. Dose predictions were produced quickly and without reliance on a planning system, enabling interactive adjustment that mirrors the clinical review-edit cycle. For the 11 patients in the test set, good control over the extent and magnitude of dose changes across 17 OOIs, together with robustness to variations in the language directives, was observed. When comparing to dose originating from a TPS, median RMSE was 52 cGy across all dose-level comparisons and 98% of predictions met the prespecified equivalence criterion of RMSE < 200 cGy. Conclusions: This work is the first to combine deep learning-based dose prediction with natural language processing specifically designed to support the language-conditioned generation of suboptimal dose distributions and their improvement. The framework could be used as a foundation for educational applications, such as replicating plan quality review in an interactive environment.

Read PDF

Similar papers

Oct 2026

Development and clinical evaluation of an automatic verification system for Oncentra brachytherapy treatment planning.

PURPOSE Current manual workflows for verification of high-dose-rate (HDR) intracavitary and hybrid interstitial brachytherapy are labor-intensive and susceptible to errors. This study developed a fully automated verification system to evaluate plan integrity, quality, and dosimetric accuracy, with the aim of improving...

Jin-Xin Peng, Jian-Ting Liu, Yong-Qiang Wang et al. · 0 citations
Open access Sep 2026

Lessons learned from implementing a transit dosimetry program: impact on patient safety.

PURPOSE Safety and quality assurance software in external beam radiotherapy may improve oncologic outcomes by enabling early detection of treatment delivery deviations. This work describes the clinical implementation of an automated in‑vivo transit dosimetry (IVTD) program and evaluates its role as a patient safety bar...

D. Sánchez-Artuñedo, A. Campos-Domenech, V. Reyes-López et al. · 0 citations
Nov 2026

Exploring a hybrid workflow on current adaptive radiotherapy systems.

PURPOSE We introduce a novel hybrid workflow in adaptive radiotherapy that combines traditional image guidance capabilities with an AI-based adaptive radiotherapy platform. METHOD The Ethos adaptive radiotherapy system currently lacks the capability for manual couch shifts at the time of treatment delivery. It offers...

Luke Layman, J. Burmeister, R. Boggula · 0 citations
Review Sep 2026

Dose equivalence calculation in radiotherapy: A Call for Standardization.

Urgent harmonization through validated models, standardized workflows with mandatory repopulation correction, voxel-based BED/EQD2 assessment, and clearly defined professional accountability is imperative to ensure consistent, safe patient care.

Cyril Voyant, D. Julian · 1 citation
Review Open access Sep 2026

Quality improvement in radiation therapy: translating printed patient education pamphlets to audiovisual digital resources

The animated video may support patient comfort and confidence during radiation therapy for breast cancer, and both pamphlets and videos appear useful for patient education, and combining them could optimize effectiveness.

Iris W. Guo, Sandra Wong, Julia Campbell et al. · 0 citations
Review Oct 2026

Daily Peer Review Reduces Replanning and Activity-Based Costs in a Network of Community Radiation Oncology Centers.

BACKGROUND AND OBJECTIVES Peer review of radiation therapy plans is an essential quality assurance process; however, when performed after the initial treatment plan has already been created, it can lead to avoidable replanning, delays, and increased resource utilization. In this study, we implemented a quality improvem...

N. Thaker, Zack Varughese, Chirag Shah et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.