Transaxillary Versus Transfemoral Access for Transcatheter Aortic Valve Implantation: A Propensity Score-Matched Comparison of Clinical Outcomes Using VARC-3 Endpoints
TAx-TAVI demonstrated comparable mortality, safety, and hemodynamic outcomes to TF-TAVI, with a significantly lower rate of bleeding complications, and Axillary access represents a safe and effective alternative route in patients unsuitable for transfemoral TAVI.
Abstract
Background/Objectives: Transaxillary access (TAx) is an established alternative to transfemoral access (TF) for transcatheter aortic valve implantation (TAVI) in patients with unfavorable iliofemoral anatomy. While TAx-TAVI has been increasingly adopted at experienced centers, propensity score-matched comparative data with VARC-3 endpoint definitions are scarce, and most existing series originate from Western European cohorts. We aimed to address this gap by reporting outcomes from a propensity-matched TAx versus TF cohort using VARC-3 endpoints, contributing contemporary data from a high-volume Turkish center with established alternative access expertise. Methods: Among 2389 consecutive TAVI procedures screened between January 2016 and December 2024, 291 patients with complete data were included. After stratification by access route (TAx n = 51; TF n = 240) and exclusion of one TAx patient with missing covariates, 1:2 greedy nearest-neighbor propensity score matching was performed using nine covariates. The final cohort comprised 150 patients (50 TAx, 100 TF). All outcomes were defined per VARC-3 criteria. Results: All nine covariates achieved standardized mean differences <0.1 after matching. Technical success was comparable (TAx 94.0% vs. TF 96.0%; p = 0.686). The VARC-3 early safety event rate did not differ significantly (16.0% vs. 15.0%; p = 1.000); no equivalence can be inferred given the small event counts and wide confidence intervals. Any bleeding (VARC-3) was significantly lower in the TAx group (8.0% vs. 22.0%; OR 0.31, 95% CI 0.10–0.95; p = 0.039), confirmed by conditional logistic regression for the matched structure (OR 0.32 [0.10–0.97]; p = 0.043); this should be considered an exploratory finding. Thirty-day all-cause mortality (encompassing in-hospital deaths) (6.0% vs. 10.0%; p = 0.545), 1-year mortality (12.0% vs. 16.0%; p = 0.628), and Kaplan–Meier 1-year survival (88.0% vs. 84.0%; log-rank p = 0.510) did not differ significantly. ICU stay (median 2 [1–2] vs. 2 [1–3] days; p = 0.020) and hospital stay (median 5 [4–6] vs. 5 [4–6] days; p = 0.005) yielded statistically significant p-values; however, medians were identical in both comparisons, and significance was driven by outlier-prolonged admissions in the TF group rather than a meaningful difference in typical recovery duration. Conclusions: TAx-TAVI demonstrated comparable mortality, safety, and hemodynamic outcomes to TF-TAVI, with a significantly lower rate of bleeding complications. Axillary access represents a safe and effective alternative route in patients unsuitable for transfemoral TAVI.
Background & Objective: Transfemoral (TF) access is the standard approach for transcatheter aortic valve replacement (TAVR), whereas transaxillary (TAx) access is reserved for patients with unsuitable femoral anatomy. Although previous studies have compared these approaches in the general TAVR population, evidence spec...
Zartasha Rahim, Maryam Motasim, Arah Khan et al.· Journal of Saidu Medical Col...· 0 citations
INTRODUCTION
Degeneration of bioprosthetic aortic valves is a common late complication. While redo surgical aortic valve replacement (redo-SAVR) has traditionally been the standard of care, transcatheter valve-in-valve implantation (ViV-TAVR) has emerged as a less invasive alternative. This meta-analysis aimed to compa...
Pouya Ebrahimi, Maryam Taheri, M. Mahalleh et al.· Heart, Lung and Circulation· 0 citations
BACKGROUND
Despite continuous advancements in devices and techniques, transcatheter aortic valve implantation remains associated with complications impacting outcomes. In 2021, the Valve Academic Research Consortium (VARC) introduced the VARC-3 criteria to better classify procedural complications.
METHODS
We conducte...
F. Giacobbe, Francesco Bruno, M. Brero et al.· Journal of the American Hear...· 0 citations
BACKGROUND
Limited data are available comparing clinical outcomes between bicuspid and tricuspid patients following transcatheter aortic valve replacement (TAVR).
OBJECTIVES
This study sought to investigate 5-year clinical outcomes in patients with severe aortic stenosis following TAVR with contemporary balloon-expan...
Kazuki Suruga, V. Patel, H. Shitan et al.· JACC: Cardiovascular Interve...· 1 citation
Background The transaxillary (TxA) approach for minimally invasive aortic valve replacement (MICS-AVR) is a sternum-sparing technique that combines surgical valve replacement with virtually no visible scarring. We report institutional outcomes of the first 1,848 consecutive TxA MICS-AVR procedures. Methods This retrosp...
S. Arzt, K. Alexiou, Ali Taghizadeh-Waghefi et al.· Annals of Cardiothoracic Sur...· 0 citations