Skip to content
Conference

Analytical Investigation of the Humidity Effects on Repetitive Partial Discharge Inception Voltage in Inverter-Fed Motor Windings

Jul 2026 · Electrical Insulation Conference · pp. 1-4 · 0 citations · 2 references

Abstract

Inverter-fed motors are exposed to high dv/dt surge voltages that can initiate partial discharge (PD) in winding insulation, particularly under humid operating conditions. This study examines the effects of humidity on the repetitive PD inception voltage (RPDIV) using twisted-pair samples and a SiC-MOSFET-based pulse power supply. Experimental results show that RPDIV decreases with increasing humidity. Analysis based on the volume-time theory indicates that this reduction is primarily caused by an increase in the electron emission from the insulation coating, while the influence of electron detachment from negative ions in air is negligible even in the high-humidity environment.

View source

Similar papers

Open access Aug 2026

Development Characteristics of Winding Interturn Insulation Partial Discharge in a Full-Scale Converter Transformer

To investigate the development characteristics of winding interturn insulation partial discharge in a full-scale converter transformer, an interturn insulation defect specimen was installed inside a ±400 kV full-scale converter transformer. A partial-discharge test was conducted under stepwise alternating-current (AC)...

Yunpeng Tang, Shu-Chen Ma, Hong Liu et al. · 0 citations
Open access Jul 2026

The impact of electric arc furnaces on voltage fluctuations in the steelworks power supply line

The electric arc of a three-phase AC furnace is used as an energy source for melting scrap metal. The nonlinear nature of the electric arc directly affects voltage quality. This article presents an analysis of voltage variations recorded simultaneously at six points in the arc furnace power supply network. Results from...

Z. Olczykowski · 0 citations
Conference Aug 2026

Research and application of power cable insulation condition testing technology based on short-time AC oscillating wave excitation

This paper proposes a short-time AC voltage (STAC)-based insulation testing method for power cable lines, addressing the critical issue of cable insulation damage caused by space charge accumulation under DC oscillating wave excitation and overcoming the limitation of excessively short peak duration in existing methods...

Youxiang Yan, Tong Wu, Hong Chen et al. · 0 citations
Conference Aug 2026

Comparative Study of IGBT Lifetime Damage in Photovoltaic Inverters Under Different MPPT Control Methods

To address thermal-fatigue damage in power devices of photovoltaic inverters, this paper investigates a three-phase photovoltaic inverter and establishes a fourth-order Foster thermal-network model based on IGBT power-device parameters. Five MPPT control methods, namely fixed duty cycle, fixed-step perturb and observe...

Wen Li, Chunjie Wang, Kaixin Liu et al. · 0 citations
Open access Jul 2026

Identification of Partial Discharge Phenomena in Glass Insulator Testing Using HFCT

Insulators are vital components in electrical power transmission systems, yet they are susceptible to degradation caused by electrical and environmental stresses. This study aims to analyze Partial Discharge (PD) characteristics in glass and porcelain insulators as an early indicator of insulation failure. Experimental...

Syofyan Anwar Syahputra, Muhammad Fadlan Siregar, Muhammad Ikhwan Fahmi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.