Skip to content
Open access

Robust Design of Tuned Viscous Mass Dampers for Wind-Induced Vibration Control of High-Rise Buildings: An Info-Gap Decision Theory Approach to Manufacturing Uncertainty

Jul 2026 · Buildings · Vol 16, pp. 2931 · 0 citations · 48 references

Abstract

Tuned viscous mass dampers (TVMDs) are effective devices for wind-induced vibration control in supertall buildings, but their performance depends on a precise resonance condition that can be disturbed by manufacturing tolerances. This study identifies an insufficiently examined asymmetric sensitivity mechanism, termed the “dangerous diagonal effect”, in which opposite-sign errors in TVMD inertance and stiffness amplify tuning-frequency drift and create a worst-case sensitivity space that conventional symmetric uncertainty models may underestimate. To tackle this challenge without requiring prior statistical distributions unavailable at the design stage, an Info-Gap Decision Theory (IGDT) robust optimization framework tailored to TVMDs under stochastic wind excitation is developed. A Kriging-metamodel-assisted Efficient Global Optimization bi-level strategy reduces the computational burden of the nested worst-case search. Applied to a 76-story, 306 m benchmark building under a dual-criterion constraint combining the ISO 10137 comfort limit and a 30% relative degradation bound, the framework certifies comfort compliance for manufacturing errors up to 23.44% along the dangerous-diagonal direction. Under the most severe coupled degradation scenario, which integrates opposite-sign manufacturing detuning, 50-year power-law aging, and Arrhenius thermal drift, the nominal H2-optimal design collapses to 36.7% vibration reduction efficiency while the IGDT robust design sustains 51.7%, reducing the Monte Carlo failure probability from 3.8% to 1.2% across 500 random realizations. An aeroelastic wind tunnel campaign spanning 620 detuning configurations on a 1:350 scaled model provides physical validation of IGDT design reliability for a TVMD system. The experiments corroborate the dangerous-diagonal sensitivity asymmetry, support the predicted robustness plateau under severe parameter detuning, and show that the IGDT framework maintains comfort compliance where the H2-optimal design fails.

Read PDF

Similar papers

Open access Aug 2026

Interval type-2 fuzzy α-plane minimax co-design of multi-tuned mass dampers for broadband vibration control under bounded uncertainty

Passive tuned mass dampers are effective near their design frequencies but can lose performance or exceed travel limits when structural properties are imprecise. This paper develops an interval type-2 fuzzy α-plane minimax method for the simultaneous allocation, tuning, and damping design of a three-absorber bank on a...

Sulieman Ibrahim Mohammad, Yogeesh Nijalingappa, Seif Al Bustanji et al. · 0 citations
Dec 2026

Experimental Evaluation of a Hybrid Vibration Control System for Antenna Masts atop Super-High-Rise Structures via Combined Shake Table–Wind Tunnel Tests

Antenna masts atop super-high-rise structures (AM–SHRSs) are highly susceptible to whiplash effects and fatigue damage under concurrent earthquake–wind excitations. To enhance their resilience, a hybrid vibration control system (HVCS) composed of isolation bearings, viscous dampers, and metallic dampers was develop...

Can-Hua Liu, Hongnan Li, Chao Li · 0 citations
Review Open access 2026

Optimization of Vibration Isolation Systems for Vibratory Rollers: From Passive Cab Mounts to Quasi-Zero-Stiffness and Intelligent Control - A Critical Review

Vibratory rollers expose operators to a coupled vibration environment generated by terrain irregularity, drum excitation, frame motion, and low-frequency resonances of the cab and seat. This critical review examines the evolution of vibration-isolation optimization for vibratory rollers from passive rubber and hydrauli...

N. Thanh · 0 citations
Aug 2026

Design and control of a variable-stiffness maglev vibration isolation system under broadband excitation

Broadband stochastic vibrations have become a critical bottleneck limiting the measurement accuracy and operational stability of precision equipment in marine engineering and resource exploration. Conventional passive isolation and linear feedback control methods suffer from limited bandwidth and insufficient robustnes...

Bo Zhou, Changming Dai, Wenxin Yi et al. · 0 citations
Review Open access Sep 2026

Supervisory Multiple-Model Adaptive Preview LQR Control of a One-Story Active Mass Damper Under Scaled Earthquake Excitation

Active mass damper control must reduce structural motion while respecting finite stroke and available actuator voltage under changing plant dynamics. This study develops a Supervisory Multiple-Model Adaptive Preview Linear Quadratic Regulator (SMMAP-LQR) for an offline numerical one-story structure under scaled earthqu...

Abdullah Çakan, H. Sezgen · 0 citations