Skip to content
Open access

Effects of ultrasound-guided ipsilateral internal jugular vein compression on catheter malposition during ultrasound-guided right infraclavicular subclavian venous catheterisation: a randomised controlled trial.

Sep 2026 · Anaesthesia · 0 citations · 24 references
Medicine

TL;DR

It is found that catheter malposition occurred less frequently in the IJV compression group, and can be an effective intervention to prevent catheter malposition during ultrasound-guided right infraclavicular subclavian venous catheterisation.

Abstract

INTRODUCTION Central venous catheter malposition into the ipsilateral internal jugular vein (IJV) is an unresolved concern in ultrasound-guided right infraclavicular subclavian venous catheterisation. We sought to investigate whether ultrasound-guided ipsilateral IJV compression during guidewire advancement reduces catheter malposition during this procedure.

Methods

Adult patients undergoing elective neurosurgical procedures requiring an ultrasound-guided right infraclavicular subclavian venous catheterisation were included in this study. Patients were assigned randomly to the IJV compression group or control group. In patients assigned to the IJV compression group, external compression was applied with an ultrasound probe to physically collapse the ipsilateral proximal IJV during guidewire advancement. The primary outcome was the incidence of overall catheter malposition. Secondary outcomes included the incidence of other catheterisation-related complications (e.g. catheter malposition into the ipsilateral internal jugular or contralateral brachiocephalic veins) and catheterisation performance indices (e.g. catheterisation time).

Results

A total of 157 and 158 patients were assigned randomly to the IJV compression and control groups, respectively. Overall, we found that catheter malposition occurred less frequently in the IJV compression group (9/157 (6%) vs. 20/158 (13%); difference in proportions -6.9%, 95%CI -13.3% to -0.6%; OR 0.42, 95%CI 0.18-0.95; p = 0.034). Except for longer median (IQR [range]) catheterisation times in the IJV compression group (139 (114-172 [48-298]) s vs. 114 (90-150 [50-274]) s; p < 0.001), other between-group differences in the secondary outcomes were not significant. All instances of catheter malposition into the ipsilateral IJV were corrected successfully by guidewire reinsertion under ultrasound-guided ipsilateral IJV compression with maximal force.

Discussion

Ultrasound-guided ipsilateral IJV compression during guidewire advancement can be an effective intervention to prevent catheter malposition during ultrasound-guided right infraclavicular subclavian venous catheterisation.

Read PDF

Similar papers

Open access Sep 2026

Effect of a prevention bundle for internal jugular vein malposition of peripherally inserted central catheters in children: a single-center before–after study

Background Peripherally inserted central catheters (PICCs) are widely used in pediatric intensive care units, but bedside insertion without fluoroscopy often results in catheter tip malposition into the internal jugular vein (IJV). We implemented a three-component prevention bundle consisting of head rotation toward th...

Yusuke Tokuda, Kentaro Ide, H. Okuwaki et al. · 0 citations
Oct 2026

Comparison of Success of Long-axis versus Short-axis Ultrasound-guided Right Internal Jugular Vein Cannulation in Adult Intensive Care Unit Patients: A Prospective Comparative Observational Study.

BACKGROUND Ultrasound-guided internal jugular vein (IJV) cannulation is recommended to improve the success and safety of central venous catheterization. Both long-axis and short-axis ultrasound approaches are widely practiced; however, evidence regarding their comparative performance remains inconclusive. OBJECTIVE T...

Girish Bandigowdanahalli Kumararadhya, Akshay Hiryur Manjunatha Swamy, Udit Bathla et al. · 0 citations
Open access Sep 2026

Comparison of Guidewire Passage in the Presence of Subclavian Vein Valves During Ultrasound-Guided Catheterization: A Two-Case Series

Ultrasound-guided subclavian vein catheterization significantly improves procedural success and safety; however, intra-luminal dynamic structures such as venous valves can interfere with guidewire advancement. This case series compares two distinct clinical scenarios involving pre-procedurally identified subclavian vei...

Ju Hyeon Lee, Dahye Moon, H. Heo et al. · 0 citations
Open access Sep 2026

Comparison Between the Effect of Ultrasound-Guided Rectus Sheath Block and Ultrasound-Guided Transversus Abdominis Plane Block on Postoperative Analgesia in Patients Undergoing Paraumbilical Hernia Repair Under General Anesthesia

BACKGROUND: Paraumbilical hernia repair surgeries are associated with substantial postoperative pain. Ultrasound-guided Rectus sheath block and Transversus abdominis plane block are commonly used to reduce postoperative requirement for narcotics . OBJECTIVE: For stud the efficacy of US-guided Rectus sheath block versus...

Rusul Ibrahim Khalil Karim Al-Qayyim, Mohammed Jawad Al-Kadas · 0 citations
Open access Oct 2026

Comparison of ultrasound-guided oblique-axis versus short-axis approaches for right internal jugular vein cannulation in the left decubitus position: a prospective, randomized, single-center trial

Central venous cannulation in the left decubitus position is more difficult than in the supine position and may be required when patients cannot safely return to supine. Whether the oblique-axis (OA) approach improves the success and safety of right internal jugular vein (RIJV) cannulation compared with the short...

Wen-Juan Liu, Zhe Su, Jun-Feng Zhang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.