Skip to content
Open access

Development of a novel material specific imaging algorithm and dual-energy CBCT technology for the next generation imaging solution on O-ring linacs

Sep 2026 · Physics in Medicine and Biology · Vol 71 · 0 citations
Physics Medicine

TL;DR

This study demonstrates the feasibility of DE CBCT technology on the HyperSight imaging system through a novel statistical material specific imaging algorithm and VMI-based CNR improvements and metal artifact reduction.

Abstract

Objective. Dual-energy (DE) imaging techniques using cone-beam computed tomography (CBCT) have applications for radiotherapy (RT) including material separation and quantification, improved contrast-to-noise ratios (CNR), and reduced metal artifacts. Traditional limitations of CBCT can be addressed by using HyperSight imaging on O-ring gantry RT units, however, DE imaging technologies have yet to be established for HyperSight. The objective of this study was to implement DE technology for HyperSight by developing a novel material specific imaging algorithm and adopting a virtual monoenergetic imaging (VMI) method. Approach. Images of a calibration phantom with various material inserts, including concentrations of iodine and calcium, were obtained at 80 and 140 kVp. A novel material separation algorithm was developed using DE Hounsfield unit values with statistical classification via the Mahalanobis distance and confidence filtering to differentiate six material groups (lung, soft tissue, fat tissue, iodine, calcium, bone). The algorithm includes concentration/density mapping via interpolation between calibrated values and was evaluated using an anthropomorphic phantom. VMIs were developed using an established method based on weighted addition of high- and low-energy images to quantify CNR enhancement and metal artifact reduction (MAR). Main results. Iodine and calcium were separable for concentrations above 47 mg I ml−1 and 303 mg Ca ml−1, whereas iodine and bone were separable above 25 mg I ml−1 and 1.4 g cm−3, respectively. Soft tissue, fat tissue, and lung demonstrated reasonable classification with accuracies of 94.6%, 91.7%, and 97.8%, respectively. At 75 keV, CNR improved by 52% for inner bone, 41% for liver, and 88% for exhale lung compared to the single-energy (SE) reference. At 70 keV, MAR improved by 11% compared to the SE reference. Significance. This study demonstrates the feasibility of DE CBCT technology on the HyperSight imaging system through a novel statistical material specific imaging algorithm and VMI-based CNR improvements and metal artifact reduction.

Read PDF

Similar papers

Physics in Medicine & Biology

This study demonstrates the feasibility of DE CBCT technology on the HyperSight imaging system through a novel statistical material specific imaging algorithm and VMI-based CNR improvements and metal artifact reduction.

Bryanna Smith, M. Sattarivand · 0 citations
Sep 2026

High-dose-rate prostate brachytherapy imaging optimization: A motorized sagittal three-dimensional ultrasound acquisition system.

The motorized attachment for SR3D acquisition reduced image variability and improved image quality, and may encourage broader use of sagittal reconstruction in HDR-BT, potentially improving patient outcomes.

David Contella, Chandima Edirisinghe, Kevin Barker et al. · 0 citations
Open access Sep 2026

Optimization of spectral photon-counting CT reconstruction parameters for improved detection of peritoneal metastases compared with energy-integrating detector dual-energy CT: a phantom study

To determine the best combination of reconstruction parameters on a spectral photon-counting CT (SPCCT) system to improve detection of peritoneal metastases (PMs) on virtual monoenergetic images (VMIs) at 40 keV. A spectral phantom was scanned using SPCCT and dual-energy CT (EID-DECT) at 8.5 mGy (CTDIvol). 40 keV VMIs...

J. Greffier, R. Grange, D. Dabli et al. · 0 citations
Open access Sep 2026

In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model

Objectives: To evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and Methods: A sing...

M. V. Rybertt, L.-P. Liu, P. Sahbaee et al. · 0 citations
Open access Oct 2026

Evaluating Image Quality of Cone Beam Computed Tomography Using HyperSight® on the Varian TrueBeam.

PURPOSE The study evaluated the image quality of the cone beam computed tomography (CBCT) system on Varian TrueBeam linear accelerators with HyperSight (TB-HS) and compared it with the standard TrueBeam system (TB-S). Particular emphasis was placed on changes relevant to offline adaptive radiotherapy (ART). METHODS I...

J. Lohela, S. Rytky, S. Karhula et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.